摘要
明确热泵空调器的热冷比概念,阐明空调器热冷比HCRs与空调房间需求热冷比HCRD的关系,提出HCRD的计算方法;采用模拟分析方法研究位于哈尔滨、北京、上海、深圳四城市的一套典型住宅在不同围护结构、在不同朝向、不同空调使用时段条件下的全年负荷特性,并根据热泵空调器的变工况性能特点,给出了各地节能建筑与普通建筑的HCRD范围及分布。
In this study, the definition of heating/cooling capacity ratio (HCR) of heat pump type air-conditioner was presented, and the relationship between supply HCR (HCRs) and demand HCR (HCRD) was described. The hourly loads simulated ware analyzed for a typical residential building in Haerbin, Beijing, Shanghai and Shenzhen faced to different directions and with different air- conditioner running schedules. HCRD range and distribution of ordinary buildings and energy saving buildings at different places were obtained according to the performance characteristics of the stan- dard heat pump type air- conditioner under different conditions.
出处
《制冷学报》
CAS
CSCD
北大核心
2006年第4期4-9,共6页
Journal of Refrigeration
关键词
市政工程
热冷比
模拟
热泵
房间空调器
建筑气候分区
冷热负荷
Municipal engineering
Heating/cooling capacity ratio
Simulation
Heat pump
Room air- conditioner
Climate subarea
Heating/cooling load