摘要 污闪是电力系统的严重自然灾害之一,国内外对盐密(ESDD)的影响进行了大量的研究,但对灰密(NSDD)影响的研究较少。文中以7片串普通悬式绝缘子XP-160为试品,在人工雾室中进行了大量的人工污秽试验,分析了ESDD和NSDD的变化对人工污秽绝缘子交流闪络电压的影响。试验结果表明:在人工污秽试验中,ESDD和NSDD均对绝缘子交流闪络电压有影响,与ESDD对人工污秽绝缘子串绝缘子交流闪络电压的影响一致,人工污秽绝缘子串交流闪络电压与NSDD也呈幂函数关系。在对交流闪络电压的影响上,ESDD和NSDD是相互独立的。因此,污区的划分不仅应考虑ESDD,同时也应考虑NSDD。对于7片串XP-160,文中还给出人工污秽试验条件下绝缘子串的交流污闪电压表达式。 Pollution flashover of insulator strings is one of the most serious natural disasters. A large number of studies about the influence of the equivalent salt deposit density (ESDD) on AC flashover voltage of polluted insulators have been done home and abroad, but few study done about the influence of the non-soluble deposit density (NSDD) on it is done. A lot of laboratory experiments are carried out on polluted XP-160 insulator string of 7 units in the artificial fog cabinet. Based on the tests results, the effects of both ESDD and NSDD on the AC flashover voltage of the artificial polluted XP-160 insulators are also analyzed. It shows that both ESDD and NSDD have influence on the AC flashover voltage (Uf) of the artificially polluted insulators, that the relationship between Uf and ESDD is the same as the one between Uf and NSDD in which the Uf reduces with the increase of ESDD by a power function, and that both ESDD and NSDD are mutually independent as for the influence on Uf. Therefore, while mapping a pollution level for a district, both ESDD and NSDD, should be considered. Then, it shows the relationship between the flashover voltage of an artificial contaminated XP-160 insulator string of 7 units and ESDD as well as NSDD.
出处 《中国电机工程学报》 EI CSCD 北大核心 2006年第15期24-28,共5页 Proceedings of the CSEE
基金 国家自然科学基金重大研究计划重点项目(90210026)~~
关键词 绝缘子串 等值附盐密度 灰密 交流闪络电压 人工雾室 污秽 insulator string, equivalent salt deposit density non-soluble deposit density AC flashover voltage artificial fog cabinet pollution
  • 相关文献

参考文献17

二级参考文献58

  • 1蒋兴良,武利会,司马文霞,舒立春,孙才新.低气压下XZP/XZWP4-160直流绝缘子覆冰闪络特性研究[J].中国电机工程学报,2004,24(6):111-115. 被引量:29
  • 2司马文霞,蒋兴良,武利会,舒立春,孙才新.低气压下覆冰染污10kV合成绝缘子直流电气特性[J].中国电机工程学报,2004,24(7):122-126. 被引量:71
  • 3舒立春,孙才新,顾乐观.覆冰、低气压下染污绝缘子的交流闪络特性[J].高电压技术,1995,21(2):14-18. 被引量:17
  • 4张仁豫,关志成,薛家麒,马霜.局部表面电导率——表征绝缘子污秽程度的一种新方法[J].高电压技术,1990,16(1):20-26. 被引量:19
  • 5Shu L, Sun C, Gu L, et al. Influence of low atmospheric pressure and ice-covered on performance of polluted composite insulator[C]. IEE of Japan Power& Energy, Japan, 1994.
  • 6ShuL, SunC, GuL, et al. A study on flashover characteristics of polluted composite insulator under acid fog conditions[C]. Proceeding of the 9th ISH, Graz, Austria, 1995.
  • 7Farzaneh M, Zhang J. Behavior of DC arc discharge on ice surface[C]. Proceedings of 8th international workshop on the atmospheric icing of structure, Iceland, 1998.
  • 8S Cai-xin, J Xing-liang, S Wen-xia, et al. Study of flashover performance and voltage correction of DC insulator in icing districts of altitude of 2500m and below[C]. Proceedings of 10th IWAIS, Brno,Czech Repubic, 2002.
  • 9Jiang Xingliang, Sun Caixin, Sima Wenxia, et al. AC flashover performance and voltage correction of 27.5 and 110 kV iced composite insulator at atmospheric pressure of 4000~5500m high altitude districts[C]. IEEE Powercon'2002, Kunming, China, 2002.
  • 10[6]Li Yu.Study of the influence of altitude on the characteristies of the electrical arc on polluted ice surface[D].Canada:Universite de Quebec a Chicoutimi,2002.