摘要 目的比较不同量的对比剂追加盐水后,在腹部增强扫描中对各脏器和血管的影响程度,以期达到不影响强化、减少副作用且减少造影剂用量的目的。方法75例受检者分为3组,A组单独注射对比剂100mL组,B组注射对比剂80mL追加盐水20mL组和C组注射对比剂70mL追加盐水30mL组。在常规动脉期33s和门脉期80s进行扫描。测量肝脏、脾脏、胰腺、肾脏门脉主干、主动脉及下腔静脉的CT值,比较3组间的不同。结果脾脏、胰腺、肾脏、门静脉和主动脉各门脉期在3组间均有统计学差异,进行两两比较结果表明,脾脏、胰腺、肾脏、门静脉和主动脉各门脉期在A和C组间有统计学差异,而胰腺和肾脏在门脉期仅在A和B组间无统计学差异。结论腹部MDCT扫描中,使用对比剂追加盐水冲刷技术,可减少对比剂的用量,减少肾毒性。 Objective To compare the enhancement degree of abdomen organs and vessels after different amount of contrast medium using saline flush in abdomen MDCT scanning, which aimed to not affect contrast enhancement, decreased the amount of contrast medium, and reduced the side - effect. Methods this study group consisted of 75 patients who were referred for contrast enhanced abdominal MDCT for various reasons. Patients were divided into three groups: injection of 100 mL of contrast medium only(A group), injection of 80 mL pushed with 20 mL of saline solution(B group), and injection of 70 mL pushed with 30 mL of saline solution(C gruop). Attenuation values were measured from the liver, spleen, pancreas, kidney, aorta, portal vein, and inferior vena cava. Results The portal venous phases of the spleen, pancreas, kidney, aorta, portal vein had statistically significant difference among groups A, B and C. But no statistically significant difference during the portal venous phases of the pancreas and the kidney between A group and B group. Conclusion Using a saline flush technique after the injection contrast medium in abdominal MDCT reduced waste of contrast medium and decrease in nephrotoxicity.
出处 《实用医学影像杂志》 2006年第4期205-207,共3页 Journal of Practical Medical Imaging
基金 珠海市科技局资助课题 课题编号PC20052025
关键词 多排螺旋CT 对比剂 腹部 Multi-detected helical CT Contrast medium Abdomen
  • 相关文献

参考文献6

  • 1Dorio PJ, Lee FT, Henseier KP, et al. Using a saline chaser to decrease contrast media in abdominal CT[J]. AJR, 2003, 180(4) : 929 - 934.
  • 2Yamashita Y, Komohara Y, Takahashi M, et al. Abdominal helical CT: evaluation of optimal doses of intravenous contrast material -A prospective randomized study [ J ]. Radiology, 2000, 216 (9) :718 -723.
  • 3Han JK, Kim AK, Lee KY, et al. Factors influencing vascular and hepatic enhancement at CT: experimental study on injection pro -tocol using a canine model[J ]. J Comput Assistd, 2000, 24 (3):400 - 406.
  • 4Irie T, Kajitani M, Yamaguchi M, et al. Contrast - enhanced CT with saline flush technique using two automated injectors: how much contrast medium does it save? [J]. J Comput Assist, 2002, 26(2): 287 -291.
  • 5Schoellnast H, Tillich M, Deutschmann H, et al. Abdominal multidetector row computed tomography: reduction of cost and contrast material dose using saline flush[J]. J Comput Assist,2003, 27(6): 847 - 853.
  • 6Freeny PC, Gardner JC, Gabriele vonlngersleben, et al. Hepatic helical CT: effect of reduction of iodine dose of intravenous con -trast material on hepatic contrast enhancement[J]. Radiology,1995, 197(1): 89 -93.