摘要 根据线-板式电除尘器的电场分布特征,提出线-板式电极间电场分布服从正态分布假设。在此假设下,以电晕区边缘和收尘极板表面作为边界条件,应用高斯定理导出线-板式电除尘器的电场分布理论计算式。该式与Oglesby等报道的线-板式电场的数值解有极好的一致性。研究表明,无论是单根还是多根电晕线,在电晕区外,所得场强分布式在整个线-板式电除尘器内处处连续可导。 The assumption of the normal distribution of the electric field is proposed according to the characteristics of the electric field distribution in the wire-plate electrostatic precipitator (ESP). The theoretical calculation formula for predicting the electric field distribution in the wire-plate ESP is developed by Gaussian electric flux theorem under the assumption when the outer edge of the corona and the surface of the collection electrode are taken as the boundary conditions. The values predicted by the new formula are in sound agreement with the numerical values presented by Oglesby and others. The new formula has also shown that the electric field distribution is continuous and derivable everywhere in the wire-plate ESP except in the corona region.
出处 《武汉科技大学学报》 CAS 2006年第4期356-358,382,共4页 Journal of Wuhan University of Science and Technology
基金 国家科技部技术开发研究专项资金资助项目(2002EG113032)
关键词 电除尘器 电场强度 正态分布 electrostatic precipitator electric field intensity normal distribution model
  • 相关文献

参考文献6

  • 1刘后启,林宏.电收尘器 (理论、设计、使用)[M].北京:中国建筑工业出版社,1986.22-40.
  • 2Oglesby S,Nichols G B.电除尘器[M].谭天祐译.北京:水利电力出版社,1983.35-50.
  • 3McDonald J K,Smith W,Spencer H,et al.A Mathematic Model for Calculating Electrical Condition in Wire-duct Electrostatic Precipitation Devices[J].J Apply Phys,1977,48(6):2 231-2 246.
  • 4W R 斯迈思.静电学和电动力学[M].戴世强译.北京:科学出版社,1981.14-16.
  • 5White H J.Industrial Electrostatic Precipitation[M].Massachusetts:Addison-Wesley,1963.319-323.
  • 6向晓东,陈旺生,刘新敏,李传贵,张国权.芒刺电晕极场强分析与离子风测定[J].武汉冶金科技大学学报,1999,22(1):39-41. 被引量:8

二级参考文献1

  • 1鲍重光.静电技术原理[M]北京理工大学出版社,1993.

共引文献8

同被引文献24

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部