期刊文献+

Shielding calculation for the thickness of the SR facility safety shutter

Shielding calculation for the thickness of the SR facility safety shutte
下载PDF
导出
摘要 The safety shutter of the SR (synchrotron radiation) facility located at the front end of the facility is an in- dispensable component for radiation protection. Its thickness is decided by the gas bremsstrahlung produced in the SR facility storage ring by the interaction of electrons with the residual gas molecules in the vacuum chamber of the storage ring. In the calculation, the 3.5 GeV, 300 mA electron beam and a 15 m long insertion-device straight section (0.133 μ Pa) were taken into account, and the safety shutter was assumed to be located 12 m away from the end of the straight section. The EGSnrc code based on the Monte-Carlo method and empirical formulas were used, respectively, to calculate the thickness to satisfy the shielding requirement of the safety shutter at the front end of the SR facility, and the results were compared and the availability of EGSnrc was proved. The safety shutter of the SR (synchrotron radiation) facility located at the front end of the facility is an indispensable component for radiation protection. Its thickness is decided by the gas bremsstrahlung produced in the SR facility storage ring by the interaction of electrons with the residual gas molecules in the vacuum chamber of the storage ring. In the calculation, the 3.5GeV, 300mA electron beam and a 15 m long insertion-device straight section (0.133 μPa) were taken into account, and the safety shutter was assumed to be located 12 m away from the end of the straight section. The EGSnrc code based on the Monte-Carlo method and empirical formulas were used, respectively, to calculate the thickness to satisfy the shielding requirement of the safety shutter at the front end of the SR facility, and the results were compared and the availability of EGSrlrc was proved.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2006年第4期198-201,共4页 核技术(英文)
关键词 同步加速器辐射设备 防火档板 蒙特卡洛法 厚度 SR facility, Safety shutter, Monte-Carlo method, EGSnrc code
  • 相关文献

参考文献8

  • 1Tromba G, Rindi A. Nucl. Instr and Meth in Phys Res,1990, A292: 700.
  • 2National Shanghai Synchrotron Radiation Facility Center,Shanghai Synchrotron Radiation Facility Preliminary Design, P6-1,2001
  • 3Job P K, Haeffner D R, Shu D. Bremsstrahlung scattering calculations for the beam stops and collimators in the APS insertion-device beamlines, ANL/APS/TB-20, 1993.
  • 4Ferrari A, Pelliccioni M, Sala P R. Nucl. Instr and Meth in Phys Res, 1993, B83:518.
  • 5Kawrakow I, Hirayama H, Rogers D W O. The EGSrtrc Code System. Canada: National Research Council of Canada. 2003:14-15.
  • 6Ipe N, Haeffner D R, Alp E E, et al. Guide to beamline radiation shielding design at the advanced photon source,ANL/APS/TB-7, 1994.
  • 7Berger M J, Hubbell J H, Seltzer S M, et al. XCOM:Photon cross sections database, NBSIR 87-3597, 2005.
  • 8Ipe N I, Fasso A. Impact of gas bremsstrahlung on synchrotron radiation beamline shielding at the advanced photon source, Slac-Pub-6410, 1994.