摘要 目的:建立流动注射荧光法测定艾司唑仑片剂含量及其溶出度的新方法。方法:利用二氧化铅固相反应器在线氧化艾司唑仑为强荧光化合物,流动注射荧光法测定艾司唑仑含量;以中国药典溶出度测定的溶出条件,建立自动采样、测定的溶出度测定方法。结果:艾司唑仑浓度在5×10^(-8)~1×10^(-5)·mL^(-1)范围内呈良好的线性关系(r=0.999),检出限为1.0×10^(-8)·mL^(-1)。片剂中艾司唑仑20 min 溶出量不少于标示量的75%。结论:该法灵敏度高、快速、简便、准确,含量测定结果与中国药典法一致;适用于片剂中艾司唑仑含量的测定及自动、快速的药物溶出度测定。 Objective:To establish a new method to determine the content and dissolution of estazolam tablets by flow injection spectrofluorometry. Methods:Estazolam was oxidized on - line into a strongly fluorescent compound with a lead dioxide solid - phase reactor, then the content of estazolam was determined with a fluorimetric detector in flow injection system. The developed flow injection fluorimetric method was adopted for the determination of dissolution of estazolam tablets according to dissolution qualification of Chinese pharmacopoeia. Results: The calibration curve was linear over a range from 5 × 10^-8 to 1 × 10^-5 g · mL^-1 of estazolam with a regression efficient of 0. 999. The detection limit was 1.0 × 10^-8g · mL^-1 ;the dissolution was not less than 75% of labelled amount at 20 min. Conclusion: This method is automatic, rapid, simple and accurate, and is suitable for the determination of content and dissolution of estazolam tablets.
作者 康洁 张志琪
出处 《药物分析杂志》 CAS CSCD 北大核心 2006年第7期961-964,共4页 Chinese Journal of Pharmaceutical Analysis
关键词 艾司唑仑 固相反应器 在线氧化 流动注射分析 荧光分析 溶出度 estazolam solid - phase reactor on - line oxidization flow injection analysis spectrofluorometry disso- lution
  • 相关文献

参考文献8

  • 1Toyo' oka Toshimasa, Kumaki Yusuke, Kanborl Masayoshi. Determination of hypnotic benzodiazepines ( alprazohun, estazohun, and midazolam) and their metabolites in rat hair and plasma by reversed -phase liquid - chromatography with electrospray ionization mass spectrometry. J Pharm Blomed Anal,2003,30:1773
  • 2Inoue Hiroyuki, Maeno Yoshitaka, Iwasa Mineo. Use of high - performance liquid chromatography as an extraction procedure for analysis of triazohun in decomposed human muscle by gas chromatography -mass spectrometry. J Chromatogr B, 1997,701:47
  • 3Dalbo L, Verga F,Marzo A. Gas chromatographic assay for estazolamin human plasma and results of a bioequivalence study. Pharmacol Res, 1997,35 (4) :329
  • 4Tanaka Einosuke, Terada Masaru, Misawa Shogo. Simultaneous deterruination of twelve benzodiazepines in human serum using a new reversed - phase chromatographic column on a 2 - μm porous microspherical silica gel. J Chromatogr B, 1996,682 : 173
  • 5曹全胜.高效液相色谱法测定艾司唑仑注射液含量[J].中国医院药学杂志,2000,20(2):85-87. 被引量:5
  • 6蔡维平,欧阳耀国,曾浩.光催化H_2O_2氧化荧光法测定艾司唑仑[J].厦门大学学报(自然科学版),1996,35(4):570-573. 被引量:1
  • 7李国平,闫立强,于晓娟,刘淑霞.硫酸颜色反应用于荧光法测定艾司唑仑的研究[J].光谱实验室,2000,17(4):435-437. 被引量:3
  • 8蔡维平,欧阳耀国,翁颖杰,许金钩.酸解荧光分析法测定艾司唑仑[J].分析化学,1996,24(8):954-956. 被引量:2