期刊文献+

氨红外分析检测尿素合成塔泄漏 被引量:2

Detection of Urea Synthesis Reactor's Leaking with Ammonia Infrared Analysis
下载PDF
导出
摘要 尿素合成塔塔体泄漏检测是保证其安全运行的一个重要环节,目前采用的蒸汽检漏法由于存在种种弊端,已不能适应泄漏检测的需要。本文简述了氨红外分析技术检测尿素合成塔泄漏的方法、系统设置、技术特点及应用实例,说明了该技术是检测尿素合成塔泄漏的行之有效的方法。 The leak detection in urea synthesis reactor was an important link for safety moving. As there' re many infactions, the steam detection was not suitable for the need of leak detection. The leak detection method, system install, technology peculiarity and applied examples of ammonia infrared analysis to detect leak in urea synthesis reactor were introduced. This method was an effective technology in urea synthesis reactor leak detection.
作者 汪家铭
出处 《四川化工》 CAS 2006年第4期27-29,共3页 Sichuan Chemical Industry
关键词 尿素合成塔 泄漏 检测 氨红外分析 urea synthesis reactor leak detection ammonia infrared analysis
  • 相关文献

同被引文献8

  • 1曹玉泉,郗江.15MnV钢建筑结构件焊接冷裂成因及对策研究[J].热加工工艺,2004,33(7):55-57. 被引量:2
  • 2周寅仪,李勇.尿素合成塔的安全维护探讨[J].大氮肥,2007,30(1):67-69. 被引量:2
  • 3Thielsch Helmut,Cone Florence.Failures in urea reactor vessels[C]// Proceedings of the 1995 40th ammonia safety symposium,ammonia plant safety (and related facilities),Tucson,AZ,USA,1996,New York:AIChE,NY,USA,1996:232-253.
  • 4吴旭正,王桂晶,石宗扬.特种设备事故典型案例集[M].北京:航空工业出版社,2005.
  • 5Pimshtein P G.Strength of multilayer high pressure vessels[J].Chemical and petroleum engineering,1968,4(7):574-578.
  • 6吕延茂.Φ1.4 m尿素合成塔基体应力腐蚀裂纹分析[C]//全国中氮情报协作组第24次技术交流会论文集.北京:《中氮肥》杂志编辑部,2006:48-51.
  • 7丁绪淮,等译.化学工程卷Ⅱ[M].北京:化学工业出版社,1987,35.
  • 8宋天民.振动时效对焊件抗应力腐蚀的影响及机理分析[J].石油化工高等学校学报,1998,11(1):67-70. 被引量:6