摘要
一种新型的光纤辐射温度计,既可作为下限温度为75℃的比色温度计使用,又可作为两台下限温度为600℃的单色温度计使用.分析了物体表面发射率及大气光路透过率对比色及单色测温准确度的影响.
A new type optical fiber pyrometer is introduced in this paper, which can be used not only as a ratio pyrometer with a lower tempelature limit of 750 ℃, but also as two monochromatic pyromtels with a lower limit of 600 ℃ .The effects of the effectivity of real body and the atmospheric transmittance on ratio/monochromatic pyrometer readings accuracy are discussed also.
出处
《沈阳工业大学学报》
CAS
1996年第4期6-10,15,共6页
Journal of Shenyang University of Technology
基金
国家自然科学基金