期刊文献+

发生炉煤气洗涤废水封闭循环后污染物增长的平衡规律研究 被引量:2

Study on the Balance of increasing Pollutants after Closed-hoped Circulation of Wastewater of Coal Gas
下载PDF
导出
摘要 大量的实验及环境监测数据表明,烟煤煤气站发生护煤气洗涤废水长期完全封闭循环运行后,废水中以挥发酚为主的污染物浓度不会无限增长,存在着动态平衡.在平衡范围内,挥发酚浓度为1300—2000mg/L,氰化物为4—20mg/L,硫化物为35—70mg/L.研究结果表明。 large amount of experiments and monitering data showed that after circulation of coal gas washwater, the concentration of pollutants (mainly valatile phenol) does not increase unlimitedly, but reaches a dynamic equilibrium. The concentration of phenol is 1300-2000 mg/L, cyanide is 4- 20 mg/L,sulfide is 35- 70 mg/L at the range of equilibrium.The result showed that it is completely feasible to use the routine technological treatment of closed-looped circulation of pretreatment of coal gas washwater removing suspended solids and tar.
出处 《环境科学》 CAS CSSCI CSCD 北大核心 1996年第3期38-40,43,共4页 Environmental Science
关键词 发生炉煤气 洗涤废水 封闭循环 污染物 closed-looped circulation, washwater of coal gas, dynamic equilibrium.
  • 相关文献

参考文献4

  • 1陈常州,化工给排水设计,1990年,9卷,1期,28页
  • 2团体著者,水污染防治手册,1989年
  • 3朱浚黄,中国环境科学,1988年,8卷,3期,67页
  • 4章福民,环境工程,1986年,4卷,15期,5页