摘要
介绍石家庄热电四厂2号汽轮机挠性联轴器发生断裂的详细情况,分析断裂的原因,通过对机组全方位的处理,使问题得到了妥善的解决,确保了设备的安全运行。
This paper introduces the details of No. 2 turbine flexible coupling break in Shijiazhuang cogeneration power plant, analyzes the causes. The problem is resolved through the omnidirectionally treatment. The operation safely of equipment is assured.
出处
《河北电力技术》
2006年第4期33-34,共2页
Hebei Electric Power