摘要
针对预焙槽内衬修筑后搁置时间过长,侧部炭块与“人造伸腿”接触处存在不同程度伸缩缝,本文介绍了防止或减少电解槽在焙烧启动及后期出现渗漏的预防措施及出现渗漏情况的分析和处理。
If relined cell is laid aside for a long time, connections between side carbon and "man - made frozen ledge"will shringk to some ectent. The pa per presents precautions upon leakage in starting up of ceils and the troubleshooting,
出处
《轻金属》
CSCD
北大核心
2006年第8期39-42,共4页
Light Metals
关键词
电解槽
预防
渗漏
electrolysis cell
precaution
leakage