期刊文献+

简易充气式CT介入外固定器的制作和应用 被引量:3

Production and application of simple air inflation CT outer intervening fixer
下载PDF
导出
摘要 目的:探求一种CT导引、经皮穿刺活检针外固定的有效方法。方法:当活检针沿预置路径及深度进入穿刺活检靶点后,外固定器独特的空心圆台和布带设计可以有效固定活检针。结果:342例CT导引、经皮穿刺活检患者,通过外固定器固定活检针,329例取得了符合病理诊断要求的病变组织、成功率达到95.9%,可使其代替人工固定活检针。结论:简易充气式CT介入外固定是一种实用性强的介入辅助器材,并避免了医务人员和患者家属直接接触X线的危险,值得推广使用。 Objective To explore an effective methods for percutaneous biopsy needle fixing which is guided by CT. Methods After the biopsy needle gets to the destination along with the aforehand route, the unique designs of hollow cylinder and the strip can fix the biopsy needle effectively. Results In 342 cases of CT-GUIDED percutaneous biopsy, 329 cases get to the pathological organize which can make accord with pathological diagnosis requirement, and the rate of success is up to 95.9%. It can replace the artificial fixed device. Conclusion The simple gassiness retainer is a very practical assistant apparatus in CT interventionao radiongy, and prevents medical worker and patient relatives from contacting the danger of the X-ray, which worth popularizing and applying.
机构地区 解放军第
出处 《医疗卫生装备》 CAS 2006年第8期80-80,共1页 Chinese Medical Equipment Journal
关键词 外固定器 CT 介入放射学 retainer CT interventionao radiongy
  • 相关文献

同被引文献18

  • 1杨贤卫,周伟生,何蓉.CT引导下经皮肺穿刺切割活检对肺部病变的诊断价值[J].中国介入影像与治疗学,2006,3(3):161-164. 被引量:17
  • 2陈耀庭,许林锋,马海清,张靖,陈斌,骆江红,江容坚,周经兴.CT引导二步法穿刺经皮微波凝固治疗肝动脉化疗栓塞术后原发性肝癌的临床应用[J].中国介入影像与治疗学,2006,3(6):428-431. 被引量:7
  • 3Noriyuki T, Naoki M, Munehiro M, et al. CT -guided needle biopsy of small pulmonary nodules: value of respiratory gating. Radiology, 2000,217(3) :907-910.
  • 4Brian CL, Jose CV, Aaron H, et al. CT-guided intervention with low radiation dose: feasibility and experience. AJR Am J Roentgenol, 2007,188(5) : 1187-1194.
  • 5Yeow KM, See LC, Lui KW, et al. Risk factors for pneumothotax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol, 2001, 12 (11) :1305-1312.
  • 6Lopez HE, Vogl TJ, Ricke JCT, et al. CT-guided percutaneous core biopsies of pulmonary lesions. Diagnostic accuracy, complications and therapeutic impact. Acta Radiol, 2001,42 (2) : 151- 155.
  • 7陈朝爱 邓秀兰.头部CT扫描和x线摄影多功能固定器.中国医学影像学杂志,1999,:76-77.
  • 8Noriyuki T,Naoki M,Munehiro M,et al. CTguided needle bopsy of small pulmonarynodules value of respiratory gating[ J].Radiology,2000,217(3): 907-910.
  • 9Yeow KM,See LC,Lui KW,et al.Risk factorsforpneumothorax and bleeding after CT—guide percutaneous coaxial cuttingneedlebiopsy of lunglesion[J]. J Vase IntervRadiol,2001,12(11): 1305-1312.
  • 10Erlemann R,Zimmerschied A,Gilger F,et al.Punch biopsy or fine neekle aspirationbiopsy in percutaneous lung puncture[J].Radiology ,1998,38(2) : 126-134.

引证文献3

二级引证文献18