摘要
内压缩万立制氧机高压节流阀堵塞和主冷板式换热器泄漏事故的分析处理。
This article presents the malfunction analysis about the jam of the high-pressure throttle of 10000m^3/h oxygen generator for the internal compression and the leak of heat exchange device of the main cold-board pattern.
出处
《低温与特气》
CAS
2006年第4期35-38,共4页
Low Temperature and Specialty Gases
关键词
内压缩
万立制氧机
高压节流阀
二氧化碳堵塞
下层主冷板式换热器泄漏
internal compression
10000 m^3/h oxygen generator
high-pressure throttle
jam of carbon dioxide
leak of the under-lay main cold-board heat exchange device