期刊文献+

差压变送器在应用中的故障诊断与分析

Fault Diagnosis and Analysis in the Application of Differential Pressure Transmitters
下载PDF
导出
摘要 本文主要介绍了差压变送器的工作原理、常用的三种测量应用方式、主要安装方法及注意事项,使用调查法、直观法、检测法诊断差压变送器测量回路的应用故障,并重点对导压管堵塞、泄漏,平衡泄漏、气体流量测量导压管积液等问题引起的故障现象进行了重点分析。 The operating principle of differential pressure transmitters, the three application modes of measurement in common use, the main method of installation and the matters need attention are introduced in this paper. The application fault in the measure loop of differential pressure transmitters can be diagnosed by investigation method, direct-vision method and detection method. The faults caused by blockage or leakage of connecting pipe, leakage of balance, and hydrops of connecting pipe measured by gas-flow rate were analyzed primarily.
出处 《可编程控制器与工厂自动化(PLC FA)》 2006年第8期120-123,共4页 Programmable controller & Factory Automation(PLC & FA)
关键词 差压变送器 故障 导压管 Differential pressure transmitters Abort Pressure pipe