摘要 利用现代精度设计理念设计纳米三坐标测量机的结构,选用高精度的零部件进行组装,解决了传统阿贝误差问题,通过研究现代精度保障理论和技术,进行纳米级水平的误差源全面分析,推导各个不确定度分量的计算公式,根据给定的精度指标设计合理的精度,提出所需检定仪器的具体技术指标,精度设计的结果满足了纳米三坐标测量机的测量精度要求. By using advanced accuracy design concept, Nano-CMM's structure is designed, which is set-up by choosing high degree of accuracy components. The traditional Abbe error is solved due to the design of the structure of the Nano- CMM. By studying the modem accuracy ensuring theory and technique, the nanometer level's analysis of total error source of the Nano-CMM is processed. The uncertainty calculating formula is deduced. The reasonable error distributing and design are clone according to the given accuracy target. The needed nanometer level calibrating instruments'technic index are put forward. The result of accuracy design meets the measuring accuracy demand of Nano-CMM is made.
出处 《重庆大学学报(自然科学版)》 EI CAS CSCD 北大核心 2006年第8期82-86,共5页 Journal of Chongqing University
基金 国家自然科学基金重大国际合作研究项目(50420120134)
关键词 纳米三坐标测量机 阿贝误差全误差源分析 不确定度 精度设计 Nano-CMM Abbe error analysis of total error source uncertainty accuracy design
  • 相关文献

参考文献4

  • 1范光照,张所鈜,颜家钰,等.高精密机械定位平台之研制[Z].第一届海峡两岸制造技术研讨会.台湾台北:台湾大学,2000.
  • 2MCKEWON.Nanotechnology,Keynote speech[Z].4th ICMT,Taiwan:Hsinchu,1998.
  • 3FAN K C,SU C D,MOU J I.Error Analysis for Diffraction Grating Interferometric Stylus Probing System[J].Messurement Science and Technolygy,2001,12(4):482-490.
  • 4钟振周,叶赐周,梁瑞方.精密机械空间误差量测与补偿[M].台北:全华科技图书股份有限公司,2004.7.