期刊文献+

长期灌流维持肾脏功能损伤的内在机理研究 被引量:1

Researches on intrinsic mechanism of renal function during long term perfusion of kidney
下载PDF
导出
摘要 采用低温机械灌流(hypothermic machinery continuous perfusion,MP)研究离体肾脏的功能.灌流维持120 h,本地家猫肾脏功能呈现出阶段性变化,灌流72 h后肾脏功能出现明显的转折.比较灌流后肾近曲小管上皮细胞超微结构和肾皮质ATP酶活性变化,发现灌流72 h离体肾脏功能最显著的变化为近曲小管上皮细胞结构破坏;改变灌流溶液渗透压能够延迟灌流肾脏功能转折,并对近曲小管上皮细胞超微结构损伤有明显的调节作用. The renal function of off-body kidney was investigated by using hypothermic machinery continuous perfusion (MP) . Over 120 h surviving time of off-body kidneys had been obtained with artificial lifemaintainable system. It was found that the structure failure of epithelia of proximal convoluted tubules was the main factor of renal function damage at 72 h perfusion. Further research indicated that the key reason of epithelia of proximal convoluted tubules damage during perfusion was the tissue edema. The innovation was verified by changing the density of mannitol, which is an important constituent of the perfusion solution, to adjust the osmotic pressure of perfusion solution and the absorbing ability of water in proximal convoluted tubule.
出处 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2006年第8期1339-1343,共5页 Journal of Zhejiang University:Engineering Science
基金 浙江省自然科学基金资助项目(398061)
关键词 肾脏 灌流 超微结构 ATP酶活性 近曲小管 kidney perfusion ultra-structure ATPase proximal convoluted tubules
  • 相关文献

参考文献11

  • 1葛霁光,徐雨维,沈公羽,张剑波,苏群.离体肾脏保存实验研究[J].浙江大学学报(自然科学版),1992,26(6):716-721. 被引量:3
  • 2YIN Sheng-yong,GE Ji-guang,LIN Zi-fu,Variations of the Ca^2+ concentrations in calcium pools of hypo-temperature-preserved cat kidney cortex cells[C]∥ IEEE-EMBS Asia-Pacific conference on Biomedical Engineering.Hangzhou,China:[s.n.],2000:825-826.
  • 3殷胜勇,葛霁光,郭淼.猫肾低温保存过程中近曲小管超微结构变化[J].科技通报,2002,18(4):314-317. 被引量:1
  • 4殷胜勇,葛霁光,郭淼.离体灌流肾脏生理功能及其内在结构动态变化研究[J].浙江大学学报(工学版),2004,38(6):789-794. 被引量:2
  • 5MITTAL V K.Pulsatile perfusion:Better then hypothermic storage with cyclosporine as an immunosuppressant[J].Dialysis & Transplantation,1985,14(3):136-140.
  • 6COLLINS G M.The role of pulsatile flow in kidney preservation[J].Transplantation,1973,16(4):378-380.
  • 7TOLEDO-Pereyra L H.One to three days hypothermic nonpulsatile perfusion for organ preservation:A comparative study with a pulsatile perfusion technique[J].Dialysis & Transplantation,1978,7(3):976-977,989.
  • 8ROSS S A.72-hour canine kidney preservation without continuous perfusion[J].Transplantation,1976,21(6):498-501.
  • 9DREIKORN K.48-to-96-hour Preservation of canine kidneys by initial perfusion and hypothermic storage using the Euro-Collins solution[J].Europe Urology,1995,27(1):757-758.
  • 10McANULTY J F,PLOEG R J,SOURTHARD J H,et al.Successful five-day perfusion preservation of the canine kidney[J].Transplantation,1989,47(1):37-41.

二级参考文献15

  • 1SELLERS M T,HUDSON S L,YOUNG C J,et al.Improved outcomes in cadaveric renal allografts with pulsatile preservation [J]. Transplantation,1999,67(9):199-199.
  • 2POLYAK M M,ARRINGTON B,STUBENBORD W T,et al.Pulsatile machine preservation improves long-term function in the renal-allograft [J]. Transplantation,1999,67(9):79.
  • 3BOOSTER M H,WIJNEN R M,YIN M,et al.Enhanced resistance to the effect of normothermic ischemia in kidneys using pulsatile machine perfusion [J]. Transplantation Proceedings, 1993,25(6):3006-3011.
  • 4ROSS S A.72-hour canine kidney preservation without continuous perfusion [J]. Trans-Plantation,1976,21:498-501.
  • 5MARSHALL V C.Renal preservation prior to transplantation [J]. Transplantation,1980,30(3):165-166.
  • 6MCHUNLTY J F, VREUGDENHILL P K, SOUTHARD J H, et al. Use of UW cold storage solution for machine perfusion of kidney [J]. Transplantation, 1990, 22:458-462.
  • 7DREIKORN K.48-to-96-hour preservation of canine kidneys by initial perfusion and hypothermic storage using the euro-collins solution [J]. Eur Urol,1995,27(1):757-758.
  • 8MCANULTY J F,SOTHARD J H,BELZER F O,et al.Successful 7-day perfusion preservation of the canine kidney [J]. Transplantation Proceedings,1993,25(1):1642-1644.
  • 9YIN S Y, GE J G, LIN Z F, Variations of the Ca2+ concentrations in calcium pools of hypo-temperature-preserved cat kidney cortex cells [A]. IEEE-EMBS Asia-Pacific Conference on Biomedical Engineering [C]. [s.l.]: IEEE, 2000.
  • 10张剑波,Chin J Med Instrumentation,1990年,14卷,5期,268页

共引文献3

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部