摘要
给出了气敏元件反应放热率Prea的公式,并由此给出在闭室测试中气体浓度C随时间变化的微分方程。通过求解微分方程给出浓度C随时间变化的曲线,表明了气体的浓度衰减很慢,而由此带来的误差一般可以忽略。
From the formula of reaction exothermic rate, the differ closed chamber test is given. From the solution of C(t), it shows that very slowly precess in concentration attenuation and the error caused by ential equation of C(t) in the the closed tested chamber is a C can be ignored.
出处
《计测技术》
2006年第B09期15-17,共3页
Metrology & Measurement Technology
关键词
气敏元件
闭室测试
反应放热率
gas sensor
closed chamber test