摘要 CT作为检出肺部病变最准确的影像方法之一,其应用越来越广泛,但其较大的辐射剂量引起国际专业人士广泛关注,1次胸部CT扫描的X线照射剂量相当于2-25mSv,为胸部平片X线照射剂量0.3mSv)的10-100倍.如何在不影响诊断的前提下以最大可能降低CF照射剂量,成为国内外专业人士共同关心的问题。本课题就常规螺旋CT与低剂量螺旋CT对肺结节的检出进行探讨。
出处 《医用放射技术杂志》 2006年第9期23-24,共2页 Journal of Medical Radiology Technology
  • 相关文献

参考文献3

  • 1Conolly S, Hearnshaw S, Low S. et al. Low- dose spiral computedtcxncgraphy for lung- cancelr screen,Lancet.1998, 352 (9123): 235.
  • 2RusinekH, NaidichDP, McGuinnessG, et al. Pulmonarynoduledeltection: low - doseversusconventionalCT Radiology, 1998, 209 - 243.
  • 3Naidch DP, Marshall CH, Gridbin C, et al. Low- dose CT Of thelungs: preliminary observations. Radiology,1990, 175 (3): 729-731.

同被引文献21

  • 1American Cancer Scociety. Cancer facts and figures. Atlanta (GA) : American Cancer Society, 2010 : 15.
  • 2Jemal A, Siegel R, Xu JR, et al. Cancer statistics. CA Cancer J Clin, 2010,60(6) :277-300.
  • 3National Lung Screening Trial Research Team, Aberle DR, Adams AM, et al. Reduced lung-cancer mortality with low-dose computed to- mographic screening. N EnglJ Med, 2011,365(5):395-409.
  • 4Doria-Rose VP, Marcus PM, Miller AB, et al. Dose the source of death information affect cancer screening efficacy results. A study of the use of mortality review versus death certificates in four randomized trails. Clin Trails, 2010,7(1):69-77.
  • 5Marcus PM, Bergstralh EJ, Fagerstrom RM, et al. Lung cancer mortality in the Mayo Lung Project: Impact of extended follow- up. J Natl Cancer Inst, 2000,92(16):1308-1316.
  • 6Diederich S, Lenzen H, Windmann R, et al. Pulmonary nodules: Experimental and clinical studies at low-dose CT. Radiology, 1999,213(I) :289-298.
  • 7Diederich S, Wormanns D, Heindel W. Lung with low-dose CT. Eur J Radiol, 2003,45 : 2-7.
  • 8Rusinek H, Naidich DP, McGuinnesa G, et al. ule detection: Low-dose versus conventional 1998,209(1) :243-249.
  • 9Funama Y, Awai K, Liu D, et al. Detection of nodules showing ground-glass opacity in the lungs at low-dose multidetector com- puted tomography: Phantom and clinical study. J Comput Assist Tomogr, 2009,33(1) :49-53.
  • 10Mascalehi M, Mazzoni LN, Falchini M, et al. Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CT. Br J Radiol, 2012,85(1016) :1134-1139.