摘要
不同的温度参数数据处理方法有不同的计算结果,本文针对检测与评定气候环境试验设备的技术性能中存在的问题,分析了三个标准(GB11158-89、GB/T 5170.1-1995、JTM K 05-1991)的温度参数数据处理方法,比对了二组实际检测数据的计算结果,说明“绝对极值法”科学准确、简捷实用。
Different methods of data processing in temperature parameters bring different calculated results. In this paper, according to the problems in measured and evaluated technical performances of climatic environmental testing equipments ,methods of data processing in temperature parameters of three standards(GB 11158-89,GB/T 5170.1-1995, JTM K 05-1991) are analyzed and calculated results for two groups of actual measure data are compared ,The examples demonstrate that "absolute-extreme technique" is scientific ,exact, concise and practicable.
出处
《环境技术》
2006年第4期8-13,共6页
Environmental Technology
关键词
气候环境试验设备
温度参数
数据处理方法
climatic environmental testing equipment
temperature parameter
method of data processing CLC number: Tbl Document code:A