Minimizing chemical interference errors for the determination of lithium in brines by flame atomic absorption spectroscopy analysis 被引量:4

Minimizing chemical interference errors for the determination of lithium in brines by flame atomic absorption spectroscopy analysis
下载PDF
导出
摘要 Chemical interferences (ionization and oxide/hydroxide formation) on the atomic absorbance signal of lithium in FAAS analysis of brine samples are elaborated in this article. It is suggested that inadequate or overaddition of deionization buffers can lead to loss of sensitivities under particular operating conditions. In the analysis of brine samples, signal enhancing and oxide/hydroxide formation inducing signal reduction resulting from overaddition of deionization buffers can be seen with varying amounts of chemical buffers. Based on experimental results, the authors have arrived at the optimized operating conditions for the detection of lithium, under which both ionization and stable compound formation can be suppressed. This is a simplified and quick method with adequate accuracy and precision for the determination of lithium in routine brine samples from chemical plants or R&D laboratories, which contain comparable amounts of lithium with some other components. Chemical interferences (ionization and oxide/hydroxide formation) on the atomic absorbance signal of lithium in FAAS analysis of brine samples are elaborated in this article. It is suggested that inadequate or overaddition of deionization buffers can lead to loss of sensitivities under particular operating conditions. In the analysis of brine samples, signal enhancing and oxide/hydroxide formation inducing signal reduction resulting from overaddition of deionization buffers can be seen with varying amounts of chemical buffers. Based on experimental results, the authors have arrived at the optimized operating conditions for the detection of lithium, under which both ionization and stable compound formation can be suppressed. This is a simplified and quick method with adequate accuracy and precision for the determination of lithium in routine brine samples from chemical plants or R&D laboratories, which contain comparable amounts of lithium with some other components.
出处 《Rare Metals》 SCIE EI CAS CSCD 2006年第4期309-315,共7页 稀有金属(英文版)
关键词 analytical chemistry simplified method FAAS LITHIUM BRINE DEIONIZATION oxide/hydroxide formation analytical chemistry simplified method FAAS lithium brine deionization oxide/hydroxide formation
  • 相关文献

参考文献1

二级参考文献2

  • 1北京第二光学仪器厂.原子吸收分光光度计或研发分析手册[M].,1990..
  • 2程光钺 邝平先.化学中的数学模型方法[M].北京:科学出版社,2000..

同被引文献22

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部