期刊文献+

动态确定输电线路输送容量 被引量:49

Research of Dynamic Line Rating System
下载PDF
导出
摘要 开发出一种利用实际气象条件和对线路参数进行实时监测来动态确定线路输送容量的监测系统,它由多个装设在耐张输电线路杆塔上的数据采集终端和设在调度中心的一个监控管理平台构成,通过公用移动通信网分组无线电业务(GPRS)/全球移动通信系统(GSM)来完成数据采集终端与监控管理平台之间的数据传输。监控管理平台通过以太网同监控与数据采集(SCADA)系统接口实现数据交换,实现系统与调度系统软件的结合,利用专家系统对输电线路的状态进行预警分析。在硬件和软件2个方面采取相应的措施,解决了抗干扰问题。建议以电力系统安全运行的监测与稳控技术为该系统提高输电线容量提供安全保障。 A dynamic llne rating (DLR) system that can evaluate transmission capacity dynamically by measuring the actual weather condition and monitoring the on-line parameters of overhead lines is developed. The system is composed of sampling terminals installed on the dead-end configuration of a line and a control instrument equipped in the dispatching center. The data between the sampling terminals and the control instrument are transmitted through GPRS/GSM. Through Ethernet, the control instrument exchanges data with SCADA interface in order to integrate the DLR and SCADA systems. The state of the transmission lines is analyzed with an expert system. The anti-interference of high voltage is solved by improving the software and hardware which are used in the system. It is proposed that measuring and reliable control technology used in the power system be used to improve the transmission capacity of the lines for system security.
出处 《电力系统自动化》 EI CSCD 北大核心 2006年第17期45-49,共5页 Automation of Electric Power Systems
关键词 动态输送容量 GPRS/GSM 输电线路 传输容量 dynamic line rating (DLR) GPRS/GSM transmission line transmission capacity
  • 相关文献

参考文献12

二级参考文献25

  • 1刘素英,梁军,李欣唐,孙晓军.发电机功角微机测量及其应用[J].电力系统自动化,1993,17(10):42-46. 被引量:11
  • 2MORIOKA Y, TOMIYAMA K, ARIMA H et al. System Separation Equipment to Minimize Power System Instability Using Generator's Angular-velocity Measurements. IEEE Trans on Power Delivery, 1993, 8(3): 941-947.
  • 3CHEN Yun-ping, ZHANG Cheng-xue, HU Zhi-jian et al. A New Approach to Real-time Measurement of Power Angles of Generator at Different Locations for Stability Control. In:Proceedings of Power Engineering Society Winter Meeting, Vol2. 2000. 1237-1242.
  • 4PHADKE A G, PICKETT B, ADAMIAK M et al.Synchronized Sampling and Phasor Measurements for Relaying and Control. IEEE Trans on Power Delivery, 1994, 9(1):442-452.
  • 5Draft IEC 61970.Energy Management System Application Program Interface(EMS-API),Part 301:Common Information Model (CIM)
  • 6Draft IEC 61970.Energy Management System Application Program Interface(EMS-API),Part 302:Common Information Model (CIM) Financial,Energy Scheduling,and Reservation
  • 7Draft IEC 61970.Energy Management System Application Program Interface(EMS-API),Part 303:Common Information Model (CIM) SCADA
  • 8Draft IEC 61970.Energy Management System Application Program Interface(EMS-API),Part 401:Component Interface Specification Framework
  • 9Draft IEC 61970.Energy Management System Application Program Interface(EMS-API),Part 402:Common Data Access Facility
  • 10Draft IEC 61970.Energy Management System Application Program Interface(EMS-API),Part 501:CIM RDF Schema

共引文献302

同被引文献588

引证文献49

二级引证文献779

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题