摘要
在镀银石英晶片上用压电免疫方法测定了0.5~50mg/L范围内的牛血清白蛋白的浓度,得到线性响应;并较全面地研究了压电晶片的回复性使用问题,以0.2mol/L甘氨酸-盐酸(pH=2.
The determination of BSA (bovine serum albumin)with a silver plate quartz crystal microbalance(QCM) was discussed.The frequency shift was proprotional to the concentrations of BSA in the range of 0.5 ̄50 mg/L.The reusability of the electrode was studied in detail.The 0.2 mol/L glycine HCl(pH=2.0)was selected as the washing solution.
出处
《武汉大学学报(自然科学版)》
CSCD
1996年第6期676-680,共5页
Journal of Wuhan University(Natural Science Edition)
基金
国家自然科学基金