摘要
本文应用热工水力分析程序Kelap5/Mod3对巴基斯坦恰希玛核电厂2号机组(C-2)反应堆冷却剂系统的低温超压情况进行分析,计算低温超压瞬态的压力峰值,分析其是否满足低温超压保护限值。
The low temperature overpressure of reactor coolant system was analyzed for Pakistan Chashma Nuclear Power Plant Unlt-2 by using the code RelapS/Mod3. The peaking pressure of RCS has been calculated, which can determine whether the RCS would be overpressurized under low temperature transient.
出处
《核电工程与技术》
2006年第3期5-9,共5页
Nuclear Power Engineering and Technology