2Clark RH, Dykes FD, Bachman TE, et al. Intraventicular hemorrhage and high-frequency ventilation : a mata-analysis of prospective clinical trials. Pediatrics, 1996,98:1058-1065.
3Dembinski R, Max M, Bensberg R, et al. High-frequency oscillatory ventilation in experimental Lung injury: effects on gas exchange,Intensive Care Med ,2002,28:768-774.
4Courtney SE, Durand DJ. High-frequency oscillatory ventilation versus conventional mechanical ventilation for very low birth weight infants. N Engl J Med ,2002,347:643-652.
6Arthurss. Lung injuring caused by mechanical ventilator. Chdst, 1999,116:9s-11s.
二级参考文献19
1[1]Keszler M, Durand DJ. Neonatal high-frequency ventilation: past, present, and future [J]. Clin Perinatol, 2001, 28(2): 579-588.
2[2]The HIFI Study Group. High-frequency oscillatory ventilation compared with conventional mechanical ventilation in the treatment of respiratory failure in preterm infants [J]. N Engl J Med, 1989, 320(4): 88-93.
3[3]Abbasi S, Bhutani VK, Spitzer AR, et al. Pulmonary mechanics in preterm neonates with respiratory failure treated with high-frequency oscillatory ventilation compared with conventional mechanical ventilation [J]. Pediatrics, 1991, 87(3): 487-493.
4[4]Clark RH, Gerstmann DR, Null DM, et al. Prospective randomized comparison of high-frequency oscillatory and conventional ventilation in respiratory distress syndrome [J]. Pediatrics, 1992, 89(1): 5-12.
5[5]HIFO Study Group. Randomized study of high-frequency oscillatory ventilation in infants with severe respiratory distress [J]. J Pediatr, 1993, 122(1): 609-619.
6[6]Ogawa Y, Miyasaka K, Kawano T, et al. A multicenter randomized trial of high frequency oscillatory ventilation as compared with conventional mechanical ventilation in preterm infants with respiratory failure [J]. Early Hum Dev, 1993, 32(6): 1-10.
7[7]Clark RH. High frequency ventilation [J]. J Pediatr, 1994, 124(4): 661-670.
8[8]Gerstmann DR, Minton SD, Stoddard RA, et al. The Provo multicenter early HFOV trial: improved pulmonary and clinical outcomes in respiratory distress syndrome [J]. Pediatrics, 1996, 98(6): 1044-1057.
9[9]Rimensberger PC, Beghetti M, Hanguinet S, et al. First intention high-frequency oscillation with early lung volume optimization improves pulmonary outcome in very low birth weight infants with respiratory distress syndrome [J]. Pediatrics, 2000, 105(1): 1202-1208.
10[10]Pianosi PT, Fisk M. High frequency ventilation trial: nine year follow up of lung function [J]. Ealy Hum Dev, 2000, 57(2): 225-234.
3Bradbury J.Could treatment of neonatal RDS improve further? Lancet,2002,3:394.
4Reininger A,Khalak R,Kendig JW,et al.Surfactant administration by transient intubation in infants 29 to 35 weeks' gestation with respiratory distress syndrome decreases the likelihood of later mechanical ventilation:a randomized controlled trial.J Perinatol,2005,25:703-708.
5Howlett A,Ohlsson A.Inositol for respiratory distress syndrome in preterm infants.The Cochrane Library,2006,Issue 1.
6Bhuta T,Hederson-Smart DJ,Elective high frequency jet ventilation versus conventional ventilation for respiratory distress syndrome in preterm infants.The Cochrane Library,2006,Issue 1.
7Sakai T,Kamohara T,Aiba S.et al.Efficacy of early piston-type high-frequency oscillatory ventilation in infants with respiratory distress syndrome.Pediatr Pulmonol,2001,32:168-174.
8Vento G,Matassa PG,Ameglio F,et al.HFOV in premature neonates:effects on pulmonary mechanics and epithelial lining fluid cytokines.A randomized controlled trial.Intensive Care Med,2005,31:463-470.
9Lotze A,Mitcbell BR,Bulas DI,et al.Multicenter study of surfactant (beractant) use in the treatment of term infants with severe respiratory failure.Survanta in Term Infants Study Group J Pediatr,1998,132:40-47.
10Wiswell TE,Knight GR,Finer NN,et al.A multicenter,randomized,controlled trial comparing Surfaxin (Lucinactant) lavage with standard care for treatment of meconium aspiration syndrome.Pediatrics,2002,109:1081-1087.