期刊文献+

基于连续高压脉冲方波的绝缘老化寿命模型 被引量:15

A Novel Insulation Life-Span Model Under Continuous High Voltage Square Impulses for Inverter-Fed Motors
下载PDF
导出
摘要 变频电机定子绝缘承受来自逆变器的连续高压脉冲方波,其老化机理与工频正弦电压作用下具有很大差异。本文设计了一种连续高压脉冲绝缘老化试验系统,以聚酰亚胺薄膜为试验对象,研究了脉冲幅值、频率以及温度对绝缘寿命的影响,提出了基于连续高压脉冲方波的绝缘老化寿命模型。 Stator insulation of inverter-fed motors is experiencing continuous impulses with significant harmonics and transients. There are many differences in insulation aging mechanism between under continuous impulses and under sine waves. However, there are few papers which discuss the life curve under continuous impulses. In order to test insulation properties under continuous impulses, a new insulation aging test system is developed. The influences of impulse amplitude, frequency, temperature on insulation life are investigated by using polyimide film. Finally, a novel insulation life model is developed based on the above test results. It is helpful for the insulation design of inverter-fed motor.
出处 《电工技术学报》 EI CSCD 北大核心 2006年第8期44-47,共4页 Transactions of China Electrotechnical Society
基金 国家自然科学基金(50377035) 霍英东教育基金(91060) 西南交通大学博士创新基金联合资助项目。
关键词 变频电机 绝缘 老化 寿命 Inverter-fed motor, insulation, aging, life-span
  • 相关文献

参考文献12

二级参考文献32

  • 1(瑞典)朗比B 拉贝克JF 等.聚合物的老化与降解[M].北京:科学出版社,1986.45-48.
  • 2徐传骧,工程电介质物理基础与进展,1995年,82页
  • 3崔孟元(译),聚合物的老化与降解,1986年,45页
  • 4Kao K C,Electrical transport in solids,1981年,242页
  • 5Dang C P,IEEE Trans on DEI,1996年,3卷,2期,237页
  • 6Von Jouanne A, et al. Application issues for PWM adjustable speed AC motor drives. IEEE Industry Application Magazine, 1996: 10~18.
  • 7Kaufhold M. Electrical stress and failure mechanism of the winding insulation in PWM-Inverter-Fed low- vol-tage induction motors. IEEE Transactions on Industrial Electronics, 2000, 47(2): 396~402.
  • 8Suresh G, Hamid A Toliyat, et al. Predicting the transient effects of pwm voltage waveform on the stator windings of random wound induction motors. IEEE Transactions on Power Electronics,1999,14: 23~30.
  • 9Yifan Tang. Analysis of steep-fronted voltage and turn insulation failure in inverter fed AC motor. Industry Applications Conference, 1997, 1: 509~516.
  • 10Gubbala L, von Jouanne A, Enjeti P, et al. Voltage distribution in the windings of an ac motor subjected to high dv/dt PWM voltages. Power Electronics Specialists Conference, 1995,1: 579~585.