摘要 光纤陀螺的工作原理和检测方法使得它从理论上将不存在死区,光纤陀螺的死区是因为电路的交叉耦合以及输出方式造成的。文中阐述了光纤陀螺死区的测量方法,分析和推导了死区产生的机理,提出了通过引入正弦信号减小或消除死区的具体措施,并进行了试验验证。结果表明,该措施可以大大减小或消除光纤陀螺死区,同时对陀螺的静态精度不产生影响。 The working and detecting principle of FOG determines that it has no deadband. The deadband of FOG is caused by electronic crosstalking. The paper describes the measurement of deadband, analyzes and derives the mathematic expression of causing deadband. The improving method is put forward by adding the sine signal in feedback control loop. The experiment verification is made. The result shows that the method can greatly eliminate the deadband, and has no bad influence on other static performance of FOG.
出处 《中国惯性技术学报》 EI CSCD 2006年第4期53-55,66,共4页 Journal of Chinese Inertial Technology
关键词 光纤 陀螺仪 交叉耦合 消除死区 fiber optic gyro crosstalking deadband eliminating
  • 相关文献

参考文献3

  • 1Herve Lefevre. The Fiber-optic gyroscope[M]. London:Artech House, 1993.
  • 2Pavlath G A. Closed-loop fiber optic gyros[A]. Fiber Optic Gyros: 20th anniversary conference, SPIE Proceedings[C]. Vol.2837, 1996: 46-60.
  • 3宋凝芳.捷联系统用光纤陀螺精度和环境适应性关键技术研究[D].北京:北京航空航天大学宇航学院,2004.