摘要 多层CT技术发展迅速,在临床影像检查中发挥越来越重要的作用。本文对多层CT近几年在宽探测器阵列和数据采集系统、X线球管、临床应用软件等方面的开发和更新进行了阐述,了解和追随技术的进步有利于充分发挥和利用设备的功能,为临床提供最佳的影像诊断信息。 With the rapid development of muhislice CT, clinical image examination is becoming more and more important.This article reviews muhislice CT about its development and update in area detector array and Data Acquisition System (DAS), X-ray tube, clinical application software and so on, which will be helpful to bring into full play of the equipment and provide the best data for clinical imaging diagnosis.
出处 《医学综述》 2006年第18期1144-1146,共3页 Medical Recapitulate
关键词 多层CT 数据采集系统 X线球管 临床应用软件 Muhislice computed tomograph Data acquisition system X-ray tube Clinical application software
  • 相关文献

参考文献21

  • 1Hui H,David H,Dennis F,et al.Four multidetector-row helical CT:Image quality and volume coverage speed[J].Radiology,2000,215(1):55-62.
  • 2Jonas R,Kenneth B,Karen C,et al.Multisection CT:scanning techniques and clinical applications[J].Radiol Graphics,2000,20 (6):1787-1806.
  • 3Thomas F,Stefan S,Karl S,et al.Multi-detector row CT systems and image-reconstruction techniques[J].Radiology,2005,235 (3):756-773.
  • 4Alexander Z,Doris P.Unprecedented detail,speed and image quality[J].Siemens Somatom Session,2004,4(14):4-7.
  • 5Flohr T,Stierstorfer K,Ulzheimer S,et al.Image reconstruction and image quality evaluation for a 64-slice CT scanner with Z-flying focal spot[J].Med Phys,2005,32(8):2536-2547.
  • 6Catherine C.Dual source CT imaging -A new era in Computed Tomography[J].Siemens Somatom Session,2005,5(17):4-11.
  • 7Anonymous.Dual source CT imaging -The idea behind the technology[J].Siemens Somatom Session,2005,5(17):13-18.
  • 8钟朝晖,卢东生.多层螺旋CT的技术特点和临床使用及发展趋势[J].中国医学影像技术,2002,18(11):1189-1191. 被引量:3
  • 9陈克敏.多层CT的进展及临床应用[J].上海第二医科大学学报,2005,25(10):981-982. 被引量:9
  • 10Thomas F,André H,Bernd O.Speed4D technology -shifting paradigms in CT[J].Siemens Somatom Session,2003,3(13):4-9.

二级参考文献47

  • 1祁吉.医学影像学的进展对临床医学的影响[J].中国CT和MRI杂志,2003,1(1):1-5. 被引量:68
  • 2[1]Axel L.Cerebral blood flow determination by rapid-sequence computed tomography: theretical analysis.Radiology, 1980, 137(3): 679-686.
  • 3[4]Miles KA, Griffiths M R.Perfusion CT: a worthwhile enhancement?Br J Radil,2003,76(4):220-231.
  • 4[5]Gobbel GT, Cann CE, Iwamoto HS,et al. Measurement of regional cerebral blood flow in the dog using ultrafast computed tomography. Experimental validation. Stroke, 1991,22(6): 772-779.
  • 5[6]Gobble GJ,Cann CE,Fike JR,etal.Comparison of xenonenhanced CT with ultrafast CT for measurement of regional cerebral blood flow. A J N R,1993,14(3):543-550.
  • 6[7]Miles KA,Hayball MP, Dixon AK.Function images of hepatic perfusion obtained with dynamic CT.Radiology, 1993,188(2): 405-411.
  • 7[8]Koening M,Klotz E,Luka B.Perfusion CT of the brain: diagnostic approach for early detective of ischemia stroke. Radiology, 1998,209(1 ):85-93.
  • 8[9]Blomley M T,Coulden R, Dawson P.Liver perfusion studied with ultrafast CT.J C A T,1995,19(3):424-443.
  • 9[10]Gillard JH,Antoun NM,Barnet NG,et al. Reproducibility of quantitative CT perfusion imaging. Br J Radiol,2001,74(882):552-555.
  • 10[11]Cenic A,Nabavi DG,Graen RA,et al. Dynamic CT measurement of cerebral blood flow:A validation study·A J N R,1999,20(1):63-73.

共引文献64

同被引文献22

  • 1杨珂,吴建,李福生,陈英民.CT剂量指数(CTDI)的使用[J].中国辐射卫生,2005,14(1):76-77. 被引量:5
  • 2陈克敏.多层CT的进展及临床应用[J].上海第二医科大学学报,2005,25(10):981-982. 被引量:9
  • 3蒋瑾,付凯.磁共振成像技术现状[J].实用医院临床杂志,2006,3(2):81-83. 被引量:4
  • 4朱弋,杨舒波,阮兴云,徐志荣.延长CT球管寿命的方法[J].医疗卫生装备,2006,27(10):49-50. 被引量:4
  • 5关静.CT技术的发展及前景[J].西南军医,2007,9(4):110-110. 被引量:2
  • 6郭洪涛,刘勇,袁淑华.CT剂量指数(CTDI)测量研究[J].中国测试技术,2007,33(4):33-36. 被引量:33
  • 7Fuchs T,Schaller S.Spiral interpolation algorithms for multislice spiral CT-part Ⅱ:measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system[J].IEEE Trans Med Imaging,2000,19(9):835-847.
  • 8Kobayashi M,Koshida K,Suzuki S,et al.Evaluation of geometric efficiency and radiation exposure in z-axis for volume scan[J].Radiat Prot Dosimetry, 2011,143( 1 ):63-68.
  • 9Berris T,Perisinakis K,Papadakis AE,et al. Comparison of methods for assessing geometric efficiency on multi-detector CT scanners[J].Phys Med, 2013,29(3) :312-322.
  • 10Venema HW,den Heeten GJ.Subtraction helical CT angiography of intra-and extracranial vessels:technical considerations and preliminary experience[J].AJNR Am J Neuroradiol,2003, 24(7): 1491-1492.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部