结合厦门国际航空港的具体概况,介绍了消防联动工程、消防照明工程的设置方法,从办公区、设备问、库区、消防设备等方面介绍了消防探测与联动控制系统的选择和控制方法,以满足消防设计要求。
Combined with general condition of Xiamen international airport, it introduces setting method of fire fighting project and fire lighting project, and illustrates selection and control method of fire detection and linkage control system from the aspects as administrative area, equipment room, reservoir area and fire-protection equipment, in order to comfort the design requirement of fire control.
出处
《山西建筑》
2006年第19期166-167,共2页
Shanxi Architecture
关键词
消防设备
防排烟风机
探测器
fire-protection equipment, smoke extractor, detector