摘要 Summary: To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws, After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer, Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P〉0.05), Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P〉0.05), The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement ofpedicle screws. Summary: To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws, After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer, Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P〉0.05), Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P〉0.05), The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement ofpedicle screws.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第4期485-488,共4页 华中科技大学学报(医学英德文版)
关键词 spondylarthropathies TOMOGRAPHY X-ray computed imaging THREE-DIMENSION spondylarthropathies tomography X-ray computed imaging three-dimension
  • 相关文献

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部