期刊文献+

重复率气体火花开关绝缘恢复特性 被引量:24

EXPERIMENT RESEARCHES OF REP-RATE GAS SPARK GAP INSULATION RECOVERY
下载PDF
导出
摘要 在自行设计的气体火花开关上,利用双脉冲回路,对纳秒脉冲作用下N2和H2的绝缘恢复特性进行了实验研究。结果表明,在静态不吹气情况下,H2的绝缘恢复时间明显比N2短。在吹气情况下,适当的气流速度即可使绝缘恢复时间明显缩短。 This paper presents results obtained during experiment research on the insulation recovery of the rep-rate gas spark gap.Insulation recovery information has generally been obtained using a two-pulse technique while the nanoseconds pulse breaks down the gap.First,under static conditions(unblown),hydrogen gas allows an order-of-magnitude improvement in the recovery of an unblow spark gap. Under dynamic conditions(gas flow),gas between the electrodes allow a significant improvement in the switch recovery.
出处 《强激光与粒子束》 EI CAS CSCD 1996年第4期518-522,共5页 High Power Laser and Particle Beams
关键词 气体火花开关 重复率 绝缘恢复 脉冲技术 gas spark gap,rep-rate,insulation recovery,two-pulse circuit
  • 相关文献

参考文献1

  • 1许日,第五届全国高功率会议论文集,1993年

同被引文献206

引证文献24

二级引证文献159

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部