三相应急电源和并联型有源滤波器复合系统

Combined Three-phase Emergency Power Supply System with Parallel Active Power Filter
下载PDF
导出
摘要 提出了一种集三相应急电源(EPS)和并联型有源滤波器(APF)一体的复合系统。该系统应用双向PWM变换器,采用DSP数字控制技术,可以实现两方面的功能,即对负载的应急供电和对来自非线性负载的谐波和无功电流补偿。文中分别阐述了电路结构和控制策略两方面,计算机仿真初步证实了该系统的可行性。 This paper proposes a combined three-phase emergency power supply system with a parallel active power filter. Based on a bilateral PWM converter using DSP digital control scheme, it can carry out two functions: supplying the load with emergency power and compensating current harmonics and reactive power generated from the nonlinear load when it operates off-line. In this paper, the circuit configuration and control scheme are discussed, and primely verified by the computer simulation.
机构地区 浙江大学
出处 《电气自动化》 北大核心 2006年第5期29-31,共3页 Electrical Automation
关键词 应急电源 有源滤波器 复合系统 控制策略 DSP emergency power supply active power filter complex system control scheme DSP
  • 相关文献

参考文献3

  • 1Oueidat M, Sadarnac D. Multiple feedback loop control strategy for UPS system having active filter ability. Telecommunications Energy Conference, 1996. INTELEC'96, 18th International, 6-10 Oct. 1996 Pages: 450 - 453
  • 2Kamran F, Habetler T.G. A novel on-line UPS with universal filtering capabilities Power Electronics. IEEE Transactions on, Volume: 13, Issue: 3, May 1998 Pages: 410-418
  • 3王兆安 杨军 刘进军.谐波抑制和无功功率补偿[M].北京:机械工业出版社,2004..