期刊文献+

Parametric Influence on Thermal Performance of Flat Plate Closed Loop Pulsating Heat Pipes 被引量:2

Parametric Influence on Thermal Performance of Flat Plate Closed Loop Pulsating Heat Pipes
下载PDF
导出
摘要 This paper presents an experimental study on a flat plate closed loop pulsating heat pipes. It consisted of total 40 channels with square cross section (2 × 2 mm^2, 165 mm long) machined directly on an aluminum plate(180×120×3 nm^2), which was covered by a transparent plate. The working fluid employed was ethanol. As the results, the influence parameters of thermal performance were investigated, such as filling ratio, heat load and operational orientations etc. Filling ratio was found to be a critical parameter, and its effect was rather complicated. According to its values the PHP plate could have four distinct working zones with different operational characteristics and heat transfer performance. The effect of heat load on thermal performance was found to be positive, and in general, iucrcasing the heat load would improve heat transfer performance. In order to analyze the effect of gravity on thermal performance, three different heat modes and total seven tilt angles were tested and compared. Successful operation at all orientations with respect to gravity was also achieved. This paper presents an experimental study on a flat plate closed loop pulsating heat pipes. It consisted of total 40 channels with square cross section(2×2 mm2, 165 mm long) machined directly on an aluminum plate(180×120×3 mm3), which was covered by a transparent plate. The working fluid employed was ethanol. As the results, the influence parameters of thermal performance were investigated, such as filling ratio, heat load and operational orientations etc. Filling ratio was found to be a critical parameter, and its effect was rather complicated. According to its values the PHP plate could have four distinct working zones with different operational characteristics and heat transfer performance. The effect of heat load on thermal performance was found to be positive, and in general, increasing the heat load would improve heat transfer performance. In order to analyze the effect of gravity on thermal performance, three different heat modes and total seven tilt angles were tested and compared. Successful operation at all orientations with respect to gravity was also achieved.
出处 《Journal of Donghua University(English Edition)》 EI CAS 2006年第3期8-13,共6页 东华大学学报(英文版)
基金 Supported by the Ger man National Science Foundation (DFG)(No. GR412/33)
关键词 flat plate closed loop pulsating heat pipes parametric influences heat transfer characteristics. 平板闭环脉动热管 参数影响 热转变特征 PCBs
  • 相关文献

参考文献6

  • 1Akachi H,Pol ek F. Preprints10th Int . Heat Pipe Conf . 1997
  • 2Groll M,Khandekar S. Proc .3rd Int . Conf . on Transport Phenomena in Multiphase Systems . 2002
  • 3Khandekar S,Groll M,Luckchoura V. Electronics Cooling . 2003
  • 4Groll M,Khandekar S. Proc .3rd Int . Conf . on Energy and Environment . 2003
  • 5Lee W,Jung H,Ki mJ .et al. Proc .11th Int . Heat Pipe Conf . 1999
  • 6S.Khandekar,,M.Scheider,,P.Schafer,,R.kulenovic,,M.Groll.Thermofluiddynamic Study of Flat Plate Closed Loop Pulsating Heat Pipe[].Microscale Thermophysical Engineering.2002

同被引文献8

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部