摘要
根据江西省修水县郭家滩水电站1号灯泡贯流机组受油器浮动瓦烧损情况,具体分析了产生受油器浮动瓦烧损的原因,并提出解决的方案.
Based on the burnt damage condition of floating tile of oil gauge receiver of the first bulb through flow turbine unit of Guojiatan Hydropower Station, the reason of the burnt damage of floating tile was analyzed. At last, the treatment measure was put forward.
出处
《江西水利科技》
2006年第3期153-155,共3页
Jiangxi Hydraulic Science & Technology
关键词
灯泡贯流机组
受油器浮动瓦
原因分析
处理
Bulb through flow turbine unit
Floating tile of oil gauge receiver
Damage
Reason analysis
Treatment measure