摘要 目的评价UF-100与相差显微镜在血尿来源鉴别中的价值。方法选取肾内科门诊病例95例和住院病例86例,分别用UF-100与相差显微镜检查分析尿液中红细胞的信息。结果对于门诊来源病例和住院来源病例,UF-100检查的敏感性(100%和96.8%)高于相差显微镜(87.9%和85.5%),P<0.05;而相差显微镜的特异性(72.6%和91.7%)高于UF-100(51.6%和58.3%),P<0.05。结论UF-100与相差显微镜结合使用是血尿来源鉴别的最好策略。 Objective to evaluate the clinical significance of UF-100 and phase-contrast microscopyin the localization of the sites of hematuria. Methods Urine samples from 95 out patients and 86 in patients with kidney disease were measured by UF-100 and phase-contrast microscopy.Results The sensitivity of UF-100(100% and 96.8% ) are higher apparently than that of phase-contrast micrescopy(87.9% and 85.5%) in outpatients and inpatients respectively( P 〈 0.05). The speciality of UF-100(51.6% and 58. 3%) are lower apparently than that of phase-contrast microscopy(72.6% and 91.7% ) in outpatients and inpatients respectively( P 〈 0. 05). Conclusion The best strategy is to combine UF-100 and phase contrast microscopy for the localization of the sites of hematuria.
出处 《中国实验诊断学》 2006年第9期1042-1045,共4页 Chinese Journal of Laboratory Diagnosis
关键词 血尿 UF-100 相差显微镜 尿液 红细胞 hematuria Sysmex UF-100 automated urinalysis analyzer phase contrast microscopy, urine, red cell
  • 相关文献

参考文献11

  • 1Thomas J,Pillsworth JR,Virginia M,et al.Differentiation of Renal from Non-Renal Hematuria by Microscopic Examination of Erythrocytes in urine.Clin Chem,1987;33(10):1 791-1 795.
  • 2马骏龙,丛玉隆,陈淑云,周建山,丁颖.全自动尿沉渣分析仪检测尿红细胞鉴别血尿来源的探讨[J].中华医学检验杂志,1997,20(5):305-305. 被引量:54
  • 3金大鸣.UF-100型尿沉渣全自动检测仪评价[J].中华检验医学杂志,1998,22(3):61-62. 被引量:145
  • 4Hyodo E,King H.Automated Methods in Urinalysis.Clin Lab Sci 1998;11(1):44-46.
  • 5李幼姬 叶任高 等.诊断肾小球血尿的一种简便方法[J].中华内科杂志,1984,23(2):99-99.
  • 6Kohler AM,Cameron JS,Grunfeld JP.Oxford University Press.1988:21.
  • 7熊立凡,顾晓菁,董晓蓓.尿棘形红细胞在肾性和非肾性血尿鉴别中的意义[J].上海医学检验杂志,2000,15(2):74-76. 被引量:25
  • 8Delanghe JR,Kouri TT,Huber AR,et al.The role of automated urine particle flow cytometry in clinical practice.Clinica Chimica Acta 2000; 301:1-18.
  • 9ECLM.European Urinalysis Guidelines.In:Kouri T,Fogazzi G,Gant V,Hallander H,Hofmann W,Guder WG,editors,Scand J Clin Lab Invest,2000(suppl).
  • 10Product Development Division,TOA Medical Electronics.Performance of the Sysmex UF-100 fully automated urine cell analyzer.Sysmex J Int 1996;6:36-40.

二级参考文献2

共引文献205

同被引文献20

  • 1陈述枚.小儿无症状性血尿的诊断[J].新医学,2005,36(5):251-253. 被引量:10
  • 2王健,丁佑品,曾云燕,董明志,杨娟.应用病理图象分析系统做尿红细胞形态学分析诊断肾小球性血尿[J].云南医药,2005,26(3):215-217. 被引量:7
  • 3Kevin E,Meyers C.Evaluation of hematuria in children.Urol Clini North America,2004,31:559-573.
  • 4Kincaid-Smith P,Fairly K.The investigation of hematuria.Seminars Nephrology,2005,25:127-135.
  • 5Gia-Khanh N.Urine cytology in renal glomerular disease and value of G1 cell in the diagnosis of glomerular bleeding.Diag Cytopathology,2003,29:67-73.
  • 6Rath B,Turner C,Hartley B,et al.Evaluation of light microscopy to localise the site of haematuria.Arch Dis Childhood,1991,66:338-340.
  • 7Tomita M,Kitamoto Y.A new movphological classitication of urinary erythrocytes for differential diagnosis of glomerular hematuria.Clin Nephrology,1992,37:84-89.
  • 8Georgopoulos F,Schuster X,Porpaczy P,et al.Evaluation of asymptomatic microscopic haematuria-influence and clinical relevance of osmolality and PH on urinary erythrocyte morphorlogy.B J Urology,1996,78:192-196.
  • 9Nagahama D,Yoshiko K,Watanabe M,et al.A useful new classification of dysmorphic urinary erythrocytes.Clin Exp Nephrol,2005,9:304-309.
  • 10Zaman Z,Proesmans W.Dysmorphic erythrocytes and G1 cells as markers of glomerular hematuria.Pediatr Nephrol,2000,14:980-984.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部