期刊文献+

发电厂水源地供电线路优化选择

Optimize Choice of Power Supply Line for the Source of Water of Power Plant
下载PDF
导出
摘要 通过对电厂水源地供电线路的电压校验比较,证明了电厂水源地的供电线路电压等级选用10kV即能满足运行的需要,比采用35kV电压等级更为经济合理,节省了水源地供电线路和其两端相应变压器的造价,减少了整个工程项目的投资。 Through the comparison of the voltage grade for power supply line of the source of water for power plant, it is proved that 10 kV power supply line of the source of water for power plant can satisfy the needs of operation, which is more economic and reasonable than that adopting 35 kV voltage grade. The cost of power supply line for the source of water and 33 corresponding transformers at its two ends, and the investment of the project can be reduced.
作者 孙成利
出处 《电力设备》 2006年第9期72-74,共3页 Electrical Equipment
关键词 水源地 电压损失 电压偏差 发电厂 厂用电 the source of water voltage losses voltage deviation power plant service power
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部