多晶氟化镁(MgF_2)导弹整流罩内散射颗粒定量无损检测方法研究

Study on the Quantitative NDT Method for Scattering Particles in the Polycrystalline-Magnesium-Fluoride Dome for Missile
下载PDF
导出
摘要 将CCD摄像技术与计算机数字图像处理技术用于散射颗粒的定量检测,设计制造了配套设备—SG-95型散射颗粒定量检测系统,首次实现了多晶MgF2导弹整流罩散射颗粒的工程定量检测与自动计数,检测精度优于10μm。 The technology of CCD photographing and digital image processing through computer were used to test quantitatively for scattering particles in the polycrystalline-magnesium-fluoride(MgF_2 )dome of missile,its accessory facilities──SG-95 type of scattering particles testing sysytem had been designed and manufactured,80, engineering quantitative test and automatic count of scattering particles in the MgF_2 missile dome was realised for the first time. The accuracy of the testing system was better than 10μm.
作者 苏飞 王自明
出处 《材料工程》 EI CAS CSCD 北大核心 1996年第10期20-22,共3页 Journal of Materials Engineering
关键词 整流罩 散射颗粒 无损检测 数字图像处理 导弹 s:polycrystalline magnesium fluorides dome,scattering particles ,NDT(Non-destructive Test), digital image processing