摘要 针对1 000 MW超超临界机组锅炉内螺纹管垂直管屏水冷壁变压运行特性进行了理论分析。重点分析了低质量流速下的水冷壁热偏差对流量偏差的影响关系和内螺纹管传热特性以及直流锅炉水冷壁强制流动特性被自然循环特性部分低偿的流动特性。 Went along a theory analysis for the operation characteristics of 1 000 MW Ultrasupercritical boilers with vertical rifled tube platen water wall, especially went along the analysis for the influence of water wall thermal deviation on flow deviation, the heat transfer characteristic of rifled pipe and the flow characteristics of a strait boiler where the force-flow in the water wall is partly canceled out by natural circle when the flow rate is low.
作者 樊泉桂
机构地区 华北电力大学
出处 《锅炉技术》 北大核心 2006年第5期5-10,共6页 Boiler Technology
关键词 超临界机组锅炉 内螺纹管水冷壁 垂直管屏 低质量流速 运行特性 ultra-supercritical boilers unit rifled water wall vertical tube platen low mass flow rate operation characteristics