期刊文献+

U型螺钉系统固定在寰枢椎不稳中的应用 被引量:2

Application of U type screw fixation system in atlanto-axial instability
下载PDF
导出
摘要 目的探讨运用U型螺钉系统(CUF)内固定治疗寰枢椎不稳的临床效果。方法2004年1月至2005年12月,运用自行设计的CUF行C1、2椎弓根固定治疗C1不稳8例。其中枢椎齿状突骨折7例,Jefferson骨折1例,伴颈髓损伤6例。结果术中未发生神经血管损伤,术后复查寰枢关节脱位全部纠正。CT轴位扫描,32枚椎弓根钉中有2枚钉部分进入椎管,1枚钉部分进入横突孔。3个月至2年平均6个月随访,7例达到骨性融合,无断钉断棒。结论后路椎弓根钉系统固定是目前治疗C1、2不稳的较好装置。它具有固定牢固、能提拉复位且放置方便等特点。手术成功的关键在于准确置入椎弓根钉。借助U型螺钉提拉复位的同时,配合体位复位是必要的。 Objective To investigate the clinic results of surgical treatment on atlanto-axial instability through home designed CUF screw fixation system. Metheds From January of 2004 to November 2005,8 cases of atlanto-axial instability were treated with C1-2 pedicles fixation by CUF screw fixation system, There were 7 patients of odontoid fracture with dislocations of C1-2, 1 case of Jefferson fracture with half dislocation and 6 cases with cervical cord injury, Results There were no injury of nerve and blood vessel in the period of operation. Atlanto-axial instability were all reduced after surgery. Axial Computed Tomography,2 screws went into vertebral canal partly,1 screw pierced transverse foramen partly. The patients were followed up for an average 6 months (ranged 3 to 24 months). 7 cases all had bony fusion. Conclusion U type screw fixation system is better posterior pedicle screw system than others in the fixation system of C1- 2 pedicles. It has many virtues as follows:fixation firmly,redueing better and placing conveniently. It is a key point for surgical treatment successfully that placing screws exactly. Meanwhile it is nesessary to reduce anotmical position of the C1-2 vertebrae.
出处 《颈腰痛杂志》 2006年第5期344-346,共3页 The Journal of Cervicodynia and Lumbodynia
关键词 U型螺钉系统 内固定 寰枢椎不稳 U type screw internal fixation atlanto-axial instability
  • 相关文献

参考文献8

  • 1Resnick DK,Lapsiwala S. Trost GR. Anatomic Suitability of the C1-2, CompLex for pedicle serew fixation [J]. Spine.2002,27(4):1494 - 1498.
  • 2Resnick DK. Benzel EC C1-C2 Pedicle screw fixation with rigid Cantileuer beam construct:case report and technical note[J].Neurosury.2002 50( 2 ) :426-428.
  • 3Harm J. Melcher RP. Posterior C1-C2 fusion with Polyanial screw and rod fixation[J]. Spinal, 2001,26( 22 ) : 2467-2471.
  • 4Coyen TJ. Fehlings MG,Wallace MC. C1-C2, posterior cervical fusion long-term evaluation of results and efficacy [J].Neurosurgery, 1995,37,688-92 : discussion692-693.
  • 5Pickman CA sonntag VK. posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis [see comments] [J]. Neurosurgery 1998 43:275-280.
  • 6马向阳,钟世镇,刘景发,尹庆水,徐达传,赵卫东,黄文华.寰枢椎后路椎弓根螺钉固定的生物力学评价[J].中国脊柱脊髓杂志,2003,13(12):735-738. 被引量:86
  • 7王春,林锦,周之平,刘成招,刘清平.颈椎U型螺钉固定系统的设计与临床应用[J].中国脊柱脊髓杂志,2005,15(12):732-735. 被引量:5
  • 8Goel A. Desai KI. Muzumdar DP. Atlantoaxial fixation using plate and scew method:a report of 160 treated patients[J].Neurosurg, 2002,5(6) : 1351-1357.

二级参考文献17

  • 1Abumi K,Ito H,Taneichi H,et al.Transpedicular screw fixation for tramatic lesions of the middle and lower cervical spine:description of the techniques and preliminary report[J].Spinal Disord, 1994,7( 1 ): 19-28.
  • 2Joncs EL,Heller JG,Silcox DH,et al. Cervical pedicle screws versus lateral mass screws:anatomic feasibility and biomechanical comparison[J].Spine, 1997,22 (9) :977-982.
  • 3Ralph K,wolfgang R,Erich S.Biomechanical analysis of transpedicular screw fixation in the subaxial spine[J].Spine,2004,29(1 ): 1869-1875.
  • 4Abumi K,kaneda K.Pedicle screw fixation for nontraumtic lesions of the cervical spine[J].Spine,1997,22(16):1953-1963.
  • 5Abumi K,kaneda K, Shonc Y, et al. One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems[J].J Nervosurg, 1999,90( 1 ): 19-26.
  • 6Jeannert B ,Gebhard JS,Magerl F. Traspedicular screw fixation of articular mass fracture-separation:results of an anatomical study and operative technique [J].J Spinal Disord,1994,7(3):222-229.
  • 7Miller RM,Ebraheim NA,Xu R,et al. Anatomic considerration of transpedicular screw placement in the cervical spine:an analysis of two approaches[J].Spine, 1996,21(20) :2317-2322.
  • 8Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation[J].Spine,2001,26(15) :2467-2471.
  • 9Karaikovie EE,Yingsakmongkol MD,Gaines RW. Accuracy of cervical pedicle screw placement using the function technique[J]. Spine, 2001,26 (22): 2456-2462.
  • 10瞿东滨,金大地,欧阳均,赵卫东,钟世镇.几种寰枢椎后路内固定术的生物力学评价[J].医用生物力学,1999,14(4):198-201. 被引量:27