摘要
测定了点源、面源和盘状源在距HPGe探测器表面不同距离上的峰总比,研究了探测器的峰总比随样品形状和测量几何条件的变化规律,验证了同一探测器不同测量条件下峰总比基本不变的特性,给出了所使用HPGeγ谱仪的峰总比曲线。
: The source, such as point, plane and disc were measured in several sourcedetector distances for the research on invariability of the peak-to-total ratio, and the curve of peak-to-total ratio was presented.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
2006年第B09期122-125,共4页
Atomic Energy Science and Technology
关键词
HPGEΓ谱仪
峰总比
峰效率
总效率
HPGe detector
peak-to-total ratio
peak efficiency
total efficiency