期刊文献+

模拟组织深度随呼吸幅度变化剂量测量水箱的研制和应用 被引量:1

Development of an irradiation dose measuring waterphantom to simulate the change of tissue depth caused by respiration
下载PDF
导出
摘要 介绍一种新型多用辐射剂量测量水箱,应用该水箱可以模拟放射治疗中病人呼吸引起的组织或肿瘤深度变化的实际情况并进行剂量测量,从而获得该病人放疗时的“组织深度波动因子”用来校正放疗时肿瘤或组织的吸收剂量,使治疗时的肿瘤吸收剂量更准确以提高治疗效果。 This paper introduces a new irradiation dose measuring waterphantom which can simulate the change of tissue depth caused by respiration. Using this waterphantom, the tissue depth waving factor can be measured which can be used for dose correction to make the absorbed dose more accurate and to improve the effect of radiotherapy.
出处 《医疗设备信息》 2006年第9期9-10,13,共3页 Information of Medical Equipment
基金 国家知识产权局专利(200620072004.1)
关键词 辐射剂量 水箱 测量 irradiation dose waterphantom measurement
  • 相关文献

参考文献6

二级参考文献34

  • 1韩树奎,路长春.直线加速器非对称准直系统对楔形因子和楔形角的影响[J].中华放射医学与防护杂志,1995,15(6):413-415. 被引量:5
  • 2Sikpi MO and Wang Y. Ionizing radiation enhances doublestrand-break repair in rapamycin-treated ataxia telangiectasia lymphoblasts[J]. Int J Radiat Biol, 2000, 76:177-187.
  • 3Wilson GD. A new look at proliferation[J]. Acta Oncologica, 2001, 40: 989-994.
  • 4Jones B and Dale RG. Mathematical models of tumour and normal tissue response[J]. Acta Oncologica, 1999, 38: 883-893.
  • 5Budach W, Gioioso D, Taghian A, et al. Repopulation capacity during fractionated irradiation of squamous cell carcinomas and glioblastomas in vitro [J]. Int J Radiat Oncol Biol Phys, 1997, 39: 743-750.
  • 6Fowler JF. Biological factors influencing optimum fractionat ion in radiation therapy[J]. Acta Oncologica, 2001, 40: 712-717.
  • 7Baumann M, Petersen C, Schulz P, et al. Impact of overall treatment time on local control of slow growing human GL squamous cell carcinoma in nude mice treated by fractionat ed irradiation[J]. Radiother and Oncol, 1999, 50: 107-111.
  • 8Baumann M, Hertz C, Baisch H, et al. Impact of overall treatment time of fractionated irradiation on local control of human FaDu squamous cell carcinoma in nude mice[J]. Radiother and Oncol, 1994, 32:137-143.
  • 9Petersen C, Zips D, Krause M, et al. Repopulation of FaDu human squamous carcinoma during fractionated radiotherapy correlates with reoxygenation[J]. Int J Radiat Oncol Biol Phys, 2001, 51: 483-493.
  • 10Roberts SA and Hendry JH. The delay before onset of accelerated tumour cell repopulation during radiotherapy: a direct maximum-likelihood analysis of a collection of worldwide tumour-control data[J]. Radiother and Oncol, 1993, 29:69-74.

共引文献8

同被引文献6

  • 1鞠永健,王高仁,缪旭东,张良安,张金波,汤娅红,徐澄.放疗中呼吸引起的组织深度波动对吸收剂量的影响[J].中华放射医学与防护杂志,2007,27(1):78-80. 被引量:9
  • 2[1]Liu Q,McDermott P,Burmeister J.Effect of respiratory motion on the delivery of breast radiotherapy using SMLC intensity modulation[J].Med Phys,2007,34(1):347-351.
  • 3[2]Bosmans G,Van Baardwijk A,Dekker A,et al.Intra-patient variability of tumor volume and tumor motion during conventionallyfractionated radiotherapy for locally advanced on-small-cell lung cancer:a prospective clinical study[J].Int J Radiat Oncol Biol Phys,2006,66(3):748-753.
  • 4[3]Blackall JM,Ahmad S,Miquel ME,et al.MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning[J].Phys Med Biol,2006,51 (17):4147-4169.
  • 5[4]Keall PJ,Mageras GS,Balter JM,et al.The management of respiratory motion in radiation oncology report of AAPM Task Group 76[J].Med Phys,2006,33(10):3874-3900.
  • 6[5]Simon L,Giraud P,Servois V,et al.Comparative study and clinical implementation of two breathing-adapted radiotherapy techniques:dosimetric benefits for lung cancer treatment[J].Cancer Radiother,2006,10(6-7):370-376.