摘要 本文介绍一种能与传统的眼底相机匹配的眼底图像处理系统。该系统不仅具有能对患者的病历信息与眼底图像信息进行集成管理的小型数据库,还具有眼底图像处理和测量的功能模块。 We have developed an eye fundus image processing system. The fundus image formed on the digital camera is displayed on the computer and processed by the image processing software. The processing software consists of three modules. One is a small data-base used as an administration system and the storage of the information of the image before and after the processing. The second is used for image pre-processing such as image filtering, edge extracting, etc. The third is a module for measuring the shane parameters of the image.
出处 《中国医学物理学杂志》 CSCD 2006年第5期325-328,共4页 Chinese Journal of Medical Physics
基金 浙江省教育厅科技计划项目(20020436)
关键词 眼底图像 图像处理 网像测量 eye fundus image processing images shape parameters of image
  • 相关文献

参考文献5

二级参考文献24

  • 1龚沛曾 陆慰民.Visual Basic程序设计教程(6.0)版[M].北京:高等教育出版社,2001..
  • 2Choplin NT. Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry. Ophthalmology 1998; 105:2068~2076.
  • 3Wilson T et al .London: Academic Press, 1984.
  • 4Dreher AW et al . Reproducibility of topographic measurements of the normal and glaucomatous optic nerve head with the laser tomographic scanner. Am-J Ophthalmol, 1991; 111:221-9.
  • 5Wollstein G, Garway Heath DF, Hitchings RA . Identification of early glaucoma cases with the scanning laser ophthalmoscope.Ophthalmology 1998; 105(8): 1557~63.
  • 6Bathija R, Zangwill L, Beryy CC. Detection of early glaucomatous structural damage with confocal scanning laser to mography. JGlaucoma 1998; 7(2) 121~7.
  • 7Mardin CY; Horn FK. Influence of optic disc size on the sensitivity of the Heidelberg Retina Tomograph. Graefes Arch Clin Exp Ophthalmol 1998; 236(9): 641~45.
  • 8Iester M; Mikelberg FS; Drance SM. The effect of optic disc size on diagnostic precision with the Heidelberg retina tomography.Ophthalmology 1997; 104(3): 545~8.
  • 9Yamazaki K, Yoshikawa S, Kunimatsu S. Influence of myopic disc shape on the diagnostic precision of the Heidelberg retina tomograph. Jpn J Ophthalmol 1999; 43(5): 392~7.
  • 10Kamal DS; Viswanathan AC; Garway Heath DF. Detection of optic disc change with the Heidelberg retina tomograph before confirmed visual field change in ocular hypertensives converting to early glaucoma. Br J Opthalmol 1999; 83:290~294.

共引文献5

同被引文献5

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部