摘要 结合新安江水力发电厂采用的SAVR2000、HWLT型微机励磁系统探讨引起误强励的原因,并提出电流突变量闭锁双PT断线、电子磁盘多重化等方法避免误强励,通过合理设计发电机励磁回路、正确选用调节电阻、利用励磁变过流等方法有效消除误强励的危害,保证发电机安全可靠运行。 Exemplified by SAVR-2000 and the HWLT microcomputer-controlled excitation systerm adopted by Xin'anjiang Hydroelectric Power Plant, this paper concerns the cause of the faulty forced excitation and proposes several ways to avoid faulty forced excitation including the confinement of the sudden variable of electric current to double PT broken line, electronic disk multiplication and so on and so forth. Designing the excitation circuit of the generator reasonably, selecting the adjusting resistance correctly and employing the high electricity of the excitation transformer are effective ways to eliminate the harm caused by faulty forced excitation as well as to ensure the sound operation of the generator.
作者 龙俊平
出处 《继电器》 CSCD 北大核心 2006年第19期71-74,共4页 Relay
关键词 励磁系统 电子磁盘 PT(电压互感器) excitation system electronic disk PT(voltage transformer)
  • 相关文献

参考文献1

  • 1..SAVR2000发电机励磁调节器技术说明书(V2.0)[Z]..国电自动化研究院南瑞电气控制公司,,2003....