期刊文献+

细水雾灭火添加剂的研究现状与性能分析 被引量:1

原文传递
导出
摘要 利用细水雾添加剂的实验研究结果对细水雾系统的添加剂进行了分类,并结合细水雾灭火系统的灭火机理分析了添加剂对细水雾灭火性能的影响。在此基础上,对目前细水雾系统添加剂选择与确定中的问题进行了探讨并提出了该系统今后的研究方向和发展趋势。
出处 《消防技术与产品信息》 2006年第9期7-10,共4页 Fire Technique and Products Information
  • 相关文献

参考文献10

  • 1丛北华,毛涛,廖光煊.含氯化钠添加剂细水雾与油池火的相互作用[C].高等学校工程热物理研究会第十届全国学术会议,2003:677—685.
  • 2Gregory Linteris, Marc Rumminger etc. Effective Non-Toxic Metallic Fire Suppressants, Final Report , NIST, 2002.2.
  • 3Michelle D. King, Evaporation of a small water droplet containing an additive, Proceedings of the ASME National Heat Transfer Conference, Augest, 1997.
  • 4刘江虹,廖光煊,厉培德,范维澄,陆强.细水雾灭火技术研究与进展[J].科学通报,2003,48(8):761-767. 被引量:55
  • 5Andrew K. Kim, Improvement of Water Mist Performance with Foam Additives. Fire Risk Management Program Institute in Construction NRCC ,2001.
  • 6程远平,李增华.消防工程学.中国矿业大学出版社,2001.
  • 7廖光煊,丛北华,况凯骞.铁基添加剂增强细水雾灭火性能的实验研究[J].工程热物理学报,2005,26(z1):273-276. 被引量:22
  • 8杨琦.高压细水雾灭火系统技术[J].消防技术与产品信息,2003,16(10):11-14. 被引量:18
  • 9徐强,秦俊,廖光煊,毛涛.NaCl对细水雾雾特性影响的实验研究[J].南京理工大学学报,2004,28(1):34-37. 被引量:11
  • 10姚斌.细水雾与火焰相互作用的实验研究.中国科学技术大学,1996.

二级参考文献51

  • 1[1]Liu Zhigang, Kim Andrew K. Review of Water Mist Fire Suppression Systems - Part Ⅰ: Fundamental Studies.Journal of Fire Protection Engineering, 2000, 10(3): 32-50
  • 2[4]Rumminger MD, Reinelt D, Babushok Ⅵ, et al. Inhibition of Flames by Iron Pentacarbonyl. In: Halon Option Technical Working Conference, HOTWC98 Proceedings,Albuquerque. New Mexico: 1998. 1-12
  • 3[5]Linteris GT, Rumminger MD. Flame Inhibition by Ferrocene, Carbon Dioxide, and Trifluoromethane Blends:Synergistic and Antagonistic Effects Chemical and Physical Processes in Combustion. In: 1999 Fall Technical Meeting, Eastern States Sections of the Combustion Institute. 1999
  • 4[6]GT Linteris. Final Report: Effective Non-Toxic Metallic Fire Suppressants . In: NISTIR6875, National Institute of Standardsand Technology. Gaithersburg MD, 2002
  • 5NFPA 750. Standard for the installation of water mist fire protection systems. 2000 Edition National Fire Protection Association, Quincy, 2000.
  • 6Mawhinney J R, Richardson J K. A review of water mist fire suppression research and development. Fire Technology, 1997,33(1): 54-90.
  • 7Liu Z, Kim A K. A review of water mist fire suppression systems-fundamental studies. Journal of Fire Protection Engineering, 2000, 10(3): 32-50.
  • 8Pepi J S. Performance evaluation of a low pressure water mist system in a marine machinery space with open doorway. Halon Alternatives Technical Working Conference, Albuquerque, 1995.424-430.
  • 9Pepi J S. Advances in the technology of intermediate pressure water systems for the protection of flammable liquid hazards.Halon Alternatives Technical Working Conference, Albuquerque,1998.417--423.
  • 10Back G G, DiNenno P J, Hill S A, et al. Full-scale testing of water mist fire extinguishing systems for machinery spaces on US army watercraft. Naval Research Laboratory, NRL/MR/6189-96-7814,1996.