期刊文献+

原子吸收光谱法测定醋酸纤维素膜中铁 被引量:4

Determination of Iron in Cellulose Acetate Membrane by Atomic Absorption Spectrometry
下载PDF
导出
摘要 用Air-C2H2火焰原子吸收光谱法测定银锌电池醋酸纤维素膜中铁含量。介绍了样品的消化处理条件和铁最佳测定条件,铁浓度0—10μg/mL范围内呈良好线性关系。该方法的灵敏度好,准确度与精密度均能满足银锌电池研制工作的要求。测定样品中铁含量相对标准偏差均小于1.0%(测定次数n=6)。标准加入回收率均在97.3%—98.0%(n=6)范围。适用于银锌电池醋酸纤维素膜中铁的测定。 The amount of ron in cellulose acetate membrane of silver-zinc cell was determined by Air-C2H2 flame atomic absorption spectrometry. The measuring conditions were optimized, and interference factors were also considered. The method is sensitive, selective with the relative standard deviations less than 1.0% (n= 6) in six sample measures, and the standard adding recovery are in the range of 97.3%-98.0%.
出处 《光谱实验室》 CAS CSCD 2006年第5期948-951,共4页 Chinese Journal of Spectroscopy Laboratory
关键词 空气-乙炔火焰 原子吸收光谱法 银锌电池 醋酸纤维紊膜 Air-C2H2 Flame, Atomic Absorption Spectrometry, Silver-Zinc Cell, Cellulose Acetate Membrane, Iron.
  • 相关文献

参考文献6

  • 1田莉玉,甘树才,陈林.溶剂萃取原子吸收光谱法测定建材样品中微量铁[J].光谱实验室,1997,14(4):53-56. 被引量:7
  • 2鞍钢钢铁研究所 沈阳钢铁研究所.实用冶金分析[M].沈阳:辽宁科学技术出版社,1990..
  • 3B威尔茨.原子吸收光谱法[M].北京:北京地质出版社,1985.311-350.
  • 4Kellner R,Merment J.Chemical Analysis[M].New York:Scientific Publishing Company,1995.101-259.
  • 5Pearl C.Quantitative Chemical Analysis[M].New York:Scientific Publishing Company,1969.226-285.
  • 6Cramer J M.Atomic Absrption Spectrometry[M].New York:Scientific Publishing Company,1982.313-319.

二级参考文献2

  • 1《岩石矿物分析》编写组.岩石矿物分析[M]地质出版社,1991.
  • 2[日]关根达也,长谷川佑子 著,腾藤.溶剂萃取化学[M]原子能出版社,1981.

共引文献66