期刊文献+

ICP-AES测定葡萄糖酸钙中Pb、As、Cd等9个杂质元素 被引量:5

Determination of 9 Elements in Calcium Gluconate by ICP-AES
下载PDF
导出
摘要 本文应用ICP-AES直接测定了葡萄糖酸钙中的Pb、As、Cd等9个杂质元素,对样品的消解方法、基体和酸介质的影响等进行了讨论。用基体匹配法消除钙基体的干扰,9个杂质元素测定的测定范围为Pb0.0008%—0.08%,Cu、Mg0.0001%—0.01%,其余元素0.0003%—0.03%。加标回收率为95.8%—100.0%,相对标准偏差为0.16%—3.61%。 Nine elements in calcium gluconate were simultaneously determined with ICP-AES. Major constituent interference was calibrated by matrix matching. The dissolution methods of samples, and the effects of matrix and acid conditions were also discussed. The detection ranges are 0. 0008%-0. 08% for Pb,0. 0001%-0. 01% for Cu,and Mg,and 0. 0003%-0.03% for As,CA, Ni,Cr,Fe,Ni. The recoveries are in the range of 95.8%-100. 0 %. The relative standard deviation are in the range of 0.16%-3.61%. The Results are satisfactory.
出处 《光谱实验室》 CAS CSCD 2006年第5期1031-1034,共4页 Chinese Journal of Spectroscopy Laboratory
关键词 电感耦合等离子体-原子发射光谱法 葡萄糖酸钙 杂质元素 PB AS CD ICP-AES, Calcium Gluconate, Impurity Elements, Pb, As, CA.