期刊文献+

SILICON NEEDLE ARRAY ON FLEXIBLE SUBSTRATE FOR FLUID TRANSFER 被引量:1

SILICON NEEDLE ARRAY ON FLEXIBLE SUBSTRATE FOR FLUID TRANSFER
下载PDF
导出
摘要 Transdermal delivery is an attractive alternative, but it is limited by the extremely low permeability of skin. To solve this problem, a novel means--micro needle array based on micro electro-mechanical system (MEMS) technology, is provided to increase permeability of human skin with efficiency, safety and painless delivery. The fabrication method consists of a sequence of deep-reactive ion etching (DRIE), anisotropic wet etching and conformal thin film deposition. The novel technology can enable the realization of micro fabricated micro needle array on a flexible silicon substrate. The micro needle array can be mounted on non-planar surface or even on flexible objects such as a human fingers and arms. The fabricated hollow wall straight micro needles are 200 μm in length, 30 μm inner diameter, and 50 μm outer diameter with 250 μm center-to-center spacing. Flow rate test proves that the polymeric base construction is important to function of micro needles array in package. Glucose solvent tests show that surface tension is the dominant force to affect the characters of flow in micro needles channel. Transdermal delivery is an attractive alternative, but it is limited by the extremely low permeability of skin. To solve this problem, a novel means--micro needle array based on micro electro-mechanical system (MEMS) technology, is provided to increase permeability of human skin with efficiency, safety and painless delivery. The fabrication method consists of a sequence of deep-reactive ion etching (DRIE), anisotropic wet etching and conformal thin film deposition. The novel technology can enable the realization of micro fabricated micro needle array on a flexible silicon substrate. The micro needle array can be mounted on non-planar surface or even on flexible objects such as a human fingers and arms. The fabricated hollow wall straight micro needles are 200 μm in length, 30 μm inner diameter, and 50 μm outer diameter with 250 μm center-to-center spacing. Flow rate test proves that the polymeric base construction is important to function of micro needles array in package. Glucose solvent tests show that surface tension is the dominant force to affect the characters of flow in micro needles channel.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第3期387-390,共4页 中国机械工程学报(英文版)
基金 This project is supported by National Hi-tech Research and Development Program of China(863 Program, No.2005AA404220).
关键词 Micro needles array Drug delivery Flexibility Packaging Transdermal delivery Micro needles array Drug delivery Flexibility Packaging Transdermal delivery
  • 相关文献

参考文献16

  • 1ANAND G, MARK K, LI Sheng. et al. An integrated biomems fabrication technology[J]. Micromechanical Microengineering, 2001, 7:186 - 189.
  • 2DENNIS L P. Biomcms applications in medicine[C]//International Symposium On Micromechatronics and Human Science, Kawasaki,Kanagawa, Japan, 2001: 13-15.
  • 3BHATIA S N, CHEN C S. Tissue engineering at the microscale[J]. Biomedical Microdevices, 1999, 2:131- 144.
  • 4FOLCH A, TONER M. Microengineering of cellular interactions[J].Annual Review of Biomedical Engineering, 2000, 2: 227-232.
  • 5DENNIS L P. MEMS technology for biomedical applications[C]//International Symposium on Micromechatronics and Human Science, Nagoya, Japan, 2001: 102-135.
  • 6GERSTEL M S, PLACE V A. Drug delivery device. US Patent,3964482 [P], 1976-06-22.
  • 7BARRY B, WILLIAMS A. Penetration enhancers[J]. Advance Drug Delivery Review, 2003, 56: 603-608.
  • 8MARK R P. Microneedles for transdermal drug delivery[J]. Advance Drug Delivery Review, 2004, 56:581-585.
  • 9STOEBER B, LIEPMANN D. Fluid injection through out-of-plane micro needles[C]// Procecdings of the International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology, Lyon,France, 2000: 34-37.
  • 10HENRY S, MCALLISTER D V, ALLEN M G, et al. Micromachined needles for the transdermal delivery of drugs[C]//Proceeding of IEEE Workshop MEMS, Heidelberg, Germany, 1998: 494-498.

同被引文献4

引证文献1

二级引证文献6