期刊文献+

影像引导放射治疗系统 被引量:9

Image guided radiotherapy system
原文传递
导出
摘要 影像引导放射治疗(IGRT)是近年来放射肿瘤学领域最先进的治疗技术。通过新型IGRT系统,将影像获取、治疗计划设计、CT模拟定位及加速器治疗完美地整合到一套放疗系统之中,以精确实施放射治疗。目前IGRT设备主要有传统直线加速器结合影像系统、断层放射治疗机和影像引导的立体定向治疗机。现就该类新技术及其临床应用作一综述。 Image-guided radiotherapy (IGRT) system has been the most advanced treatment technique in radiation oncology in recent years. Through new IGRT, several processes can be perfectly integrated in a set of radiotherapy system for conformal therapy, which include image taking, radiotherapy planning, CT simulation and accelerator treatment. The IGRT equipment comprises traditional linear accelerator combinated with image system, helical tomotherapy and image-guided stereotaxic targeted therapy. This paper reviews new technique and the clinical uses of IGRT.
作者 沈亚丽 许峰
出处 《国际肿瘤学杂志》 CAS 2006年第9期707-710,共4页 Journal of International Oncology
关键词 影像引导 放射治疗 适形 Image guide Radiotherapy, conformal
  • 相关文献

参考文献21

  • 1Miehalski J, Purdy JA, Gaspar L, et al. Radiation Therapy Oneology Group. Research Plan 2002-2006. Image-Guided Radiation Therapy Committee. Int J Radiat Oncol Biol Phys,2001,51 (3 Suppl 2) :60-65.
  • 2Pouliot J, Bani Hashemi A,Chen J,et al. Low-dose megavoltage conebeam CT for radiation therapy. Int J Radiation Oncol Biol Phys,2005,61(2) : 552-560.
  • 3Alasti H, Petrie MP, Catton CN, et al. Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of eareinoma of the prostate. Int J Radiat Oncol Biol Phys,2001,49 ( 3 ) :869-884.
  • 4Stroom JC, Olofsenvan Acht MJ,Quint S,et al. On-line set-up corrections during radiotherapy of patients with gynecologic tumors. Int J Radiat Oneol Biol Phys,2000,46 (2):499-506.
  • 5Alasti H, Petrie MP, Catton CN, et al. Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate. Int J Radiat Oncol Biol Phys,2001,49 ( 3 ) :869-884.
  • 6Wang JW, Binns WR, Cheng AY, et al. On-line radiotherapy imaging with an array of fiber-optic image reducers. Int J Radiat Oncol Biol Phys, 1990,18 (6) : 1477-1484.
  • 7Olivera GH, Shepard DM, Reckwerdt PJ, et al. Maximum likelihood as a common computational framework in tomotherapy. Phys Med Biol,1998,43 ( 11 ) :3277-3294.
  • 8Scrimger RA, Tome WA, Olivera GH, et al. Reduction in radiation dose to lung and other normal tissues using helical tomotherapy to treat lung cancer, in comparison to conventional field arrangements. Am J Clin Oncol,2003,26( 1 ) :70-78.
  • 9Ruchala K, Olivera GH, Schloesser EA, et al. Megavoltage CT on a tomotherapy system. Phys Med Biol, 1999,44(10) :2597-2621.
  • 10Groh BA, Siewerdsen JH, Drake DG, et al. A performance comparison of flat-panel imager-based MV and kV cone-beam CT. Med Phys,2002,29 ( 6 ) :967-975.

同被引文献91

引证文献9

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部