摘要 目的对比下颈椎经关节螺钉和Magerl侧块螺钉固定技术神经根(前支和后支)损伤的潜在风险。方法应用经关节螺钉和Magerl侧块螺钉两种固定技术,固定C_(3-7)节段,每种技术使用2具标本和20枚螺钉。使用直径为3.5mm、长度为20mm的螺钉进行过度穿透侧块腹侧皮质固定。仔细解剖颈部的前侧方,观察螺钉与脊神经前、后支的关系。结果下颈椎经关节螺钉固定技术总体神经损伤比例(45%)明显低于Magerl侧块螺钉固定技术(90%),两者差异有显著性意义(P<0.05)。经关节螺钉和Magerl侧块螺钉固定技术引起的神经损伤均最多见于脊神经后支,分别为25%和45%。结论经关节螺钉固定技术神经根损伤的风险低于Magerl侧块螺钉固定技术。 Objective To compare anatomically the potential incidences of injury to the nerve roots of ventral and dorsal rami caused by the transarticular screws and Magerl lateral mass screws in the fixation of subaxial cervical spine. Methods Fixations with the transarticular screws and Magerl lateral mass screws were performed in this study. For each kind of fixation, 20 screws were inserted from C3 to C7 in two specimens. A 20-mm long screw was used to over-penetrate the ventral cortex. The anterolateral aspect of the cervical spine was carefully dissected to allow ob- servation of the screw-ramus relationship. Results The overall percentage of nerve violation was significantly lower in the transarticular screw fixation (45%) than in the Magerl lateral mass screw fixation (90%). The difference was statistically significant between the two fixation methods ( P 〈 0.05). The greatest percentages of nerve violation caused by the transarticular screws and lateral mass screws were found at the dorsal ramus, 25% and 45%, respectively. Conclusion The potential risk of nerve root violation caused by the transarticular screw technique is lower than that by the Magerl lateral mass screw technique in the lower cervical spine.
出处 《中华创伤骨科杂志》 CAS CSCD 2006年第10期965-969,共5页 Chinese Journal of Orthopaedic Trauma
关键词 下颈椎 经关节螺钉 侧块螺钉 脊神经 解剖学 Subaxial cervical spine Transarticular screw Lateral mass screws Spinal nerve Anatomy
  • 相关文献

参考文献13

  • 1Roy-Camille R.Mazel C.Saillant G.Treatment of cervical spine injuries by a posterior osteosynthesis with plates and screws.In:Kehr P.Weidner A,eds.Cervical spine.Vienna:Springer-Verlag,1987,163
  • 2Roy-Camille R.Saillant G.Chirurgie du rachis cervical:luxation-fracture des articulaires.Nouvelle Presse Medicale,1972,1:2484-2485
  • 3Takayasu M,Hara M,Yamauchi K,et al.Transarticular serew fixation in the middle and lower cervical spine. Technical note.J Neurosurg, 2003, 99(1 Suppl): 132-136.
  • 4Klekamp JW, Ugbo JL, Heller JG, et al. Cervical transfacet versus lateral mass screws: a biomechanical comparison. J Spinal Disord, 2000, 13: 515-518.
  • 5Jeanneret B, Magerl F, Ward EH, et al. Posterior stabilization of the cervical spine with hook plates. Spine, 1991, 16(Suppl) : 56-63.
  • 6Graham AW, Swank ML, Kinard RE, et al. Posterior cervical arthrodesis and stabilization with a lateral mass plate. Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications. Spine, 1996, 21:323-328.
  • 7Wellman B J, Follett KA, Traynelis VC. Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients. Spine, 1998, 23: 193-200.
  • 8Anderson PA, Henley MB, Grady MS, et al. Posterior cervical arthrodesis with AO reconstruction plates and bone graft.Spine, 1991, 16:72-79.
  • 9Fehlings MG, Cooper PR, Errico TJ. Posterior plates in the management of cervical instability: long-term results in 44 patients. J Neurosurg, 1994, 81:341-349.
  • 10DalCanto RA, Lieberman I, Inceoglu S, et al. Biomechanical comparison of transarticular facet screws to lateral mass plates in two-level instrumentations of the cervical spine. Spine, 2005,30: 897-902.

同被引文献144

引证文献18

二级引证文献56

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部