高效液相色谱法同时测定樟脑苯酚溶液中两组分的含量 被引量:9

HPLC determination of the content of camphor and phenol in camphor and phenol solution
下载PDF
导出
摘要 目的:采用高效液相色谱法同时测定樟脑苯酚溶液中两组分的含量。方法:采用 Hypersil C_(18)色谱柱(4.6 mm×200mm,5μm),以甲醇-水(70:30)为流动相,流速2.0 mL·min^(-1),紫外检测器于290 nm 测定。结果:HPLC 法测定,所测成分与溶剂分离良好,樟脑、苯酚的线性范围分别为1:53~3.58 mg·mL^(-1)(r=1.0000)和0.74~1.73 mg·mL^(-1)(r=0.9997),样品溶液在24 h 内稳定,总回收率(n=9)分别为99.9%与100.1%。结论:本法简便、快速,结果准确、可靠,重现性好。 Objective:To determine the content of camphor and phenol in camphor and phenol solution by HPLC. Methods: The column : Hypersil C18 column ( 4. 6 mm × 200 mm, 5 μm, ) ; The mobile phase : Methanol - water ( 70 : 30) ;The flow rate:2. 0 mL · min^-1 ;The detection wavelength :290 nm. Results:The detected component and host were separated well by HPLC. The linear response ranges were 1.53 - 3.58 mg · mL^- 1 ( r=1. 0000 ) for camphor and 0.74 - 1.73 mg · mL^- 1 ( r =0. 9997) for phenol ; The sample solution is steady within 24 h. The average recoveries ( n = 9) were 99. 9% and 100. 1%, respectively. Conclusion :This method is simple, rapid, accurate and reliable.
出处 《药物分析杂志》 CAS CSCD 北大核心 2006年第8期1161-1162,共2页 Chinese Journal of Pharmaceutical Analysis
关键词 高效液相色谱法 樟脑苯酚溶液 樟脑 苯酚 含量测定 HPLC camphor and phenol solution camphor phenol content determination
  • 相关文献

参考文献1

  • 1Drug specifications Promulgated by the State Drug Administration(国家药品监督管理局国家药品标准).Vol 10(第十册).2002.227