摘要
洛河发电厂二期2×300 MW投产以来,磨煤机减速箱运行中一直存在严重漏油现象。通过对现场漏油情况的分析,找出了减速箱漏油的主要原因,提出了对减速箱改进的方案。改变了减速器的润滑方式,增设了减速箱体的回油槽,改进后消除了减速箱润滑油在结合面的泄漏,增加了磨煤机运行的可靠性。
The oil leakage of reduction gearbox of the pulverizer for 2 × 300MW units has been very serious since it was put into service in Phase Ⅱ , Luohe Power Plant . Main reasons have been found and modifying method have been submitted through analysis. After modification, the oil leakage has abated, it could be used for reference in similar equipment.
出处
《电站辅机》
2006年第3期43-44,共2页
Power Station Auxiliary Equipment
关键词
减速箱
漏油
原因分新
改进
reduction gearbox
oil leakage
reasons analysis
improvement